Brochure for models with FLASH motherboard
( fi rmware version ECT2008air - & ECT2008box - )
PAGE
25
8.1 SAFETY DEVICE FOR AUGER WHEN OPENING HOPPER DOOR
When you are feeding wood pellet into the hopper, we advice to stop the stove before operation; if you just need to check into
hopper the level of wood pellets, for your safety as soon as you will open pellet door, the auger will stop automatically the feeding
of the pellet; consequently, if the stove is in “WORKING” conditions, do not leave the hopper door (see ref B) open longer then
one minute.
In case that the door will remain open longer then one minute, please always look at the combustion chamber and follow this
procedure:
- If flame is available, close the hopper door , the stove will continue burning the pellet.
- If flame is not available, switch off the stove with button 3 ; then press button 3 again (see ref. B) for restart.
- Upon delivery of each stove, the hopper safety switch must be connected. In no specific order please connect the wiring to these
two prongs.
Fig. B
SPORTELLO PELLET
16:36
65° P3
wOrKing
Fig. A
8.2 SAFETY DEVICE FOR OPENING OF FRONT DOOR
When the stove is in “WORKING” conditions, every time the front door will be open, the stoves safety system will start a count
down for a period set with parameter 35 (company setting is 10”);
After set time, the stove will shut down and display will show “NO DEPRESS”(see ref C); to reset alarm, please close the door and
then press button 3 for reset; for restarting the stove press button 3 again.
9.0 DUCTING HOT AIR. ( ELENA AIRPLUS, VERONICA, LAURA ) ONLY
Ducting hot air to other rooms can be easily done by using a 3” inch flaxible duct. The 3” inch flexible duct must be UL Listed to UL
Standard 181. To get the optimal efficiency out of your stove it is recommended not to run more than 12’ feet per duct and to use
an insulated flexible duct.
To connect the ducts to the back of your stove use a hose clamp and / or aluminum foil tape.
nO
DePress.