USER MANUAL
–
i
Forks-52 (BLE)
39
Error message
Solution
Transmission error
Database full
Underload
FRAM error
Only in default units
Configuration error
Wrong firmware F1
Wrong firmware F2
Height sensor error
G-sensor error
Data mismatch
Invalid TAC code
Invalid CAL code
Retry
Tare already active
Preset tare invalid
Invalid input
Calibration error
Ind. power too low!
Reset
BLT-Master Connect Failed
2011
No ACK received from RDC application or other communication failure.
Database for saving RDC weighing is full. Go to a point where the WLAN
connection is guaranteed to be able to delete the saved weighing and
empty the database. If the RDC application is not used, change the
setting in the user menu.
Negative gross load. Lift the forks from the floor.
There is an error with the FRAM. Contact your dealer/supplier.
The action performed is not allowed during the units switch mode. Tap
on the button ‘units switch’ first or wait until the units switch back to the
original units automatically (after 3 seconds).
There is a problem with the configuration of the hardware. Most likely to
happen after a spare part replacement. Contact your dealer/supplier.
The software in the fork module 1 is not in correspondence with the
firmware release of the indicator. Contact your dealer/supplier.
The software in the fork module 2 is not in correspondence with the
firmware release of the indicator. Contact your dealer/supplier.
The output of the height sensor of the fork modules differ too much.
Contact your dealer/supplier.
The output of the G-sensor of the fork modules differ too much.
Contact your dealer/supplier.
The Master module receives corrupted data. Contact your supplier/
dealer.
The TAC code entered is incorrect.
The CAL code entered is incorrect.
Incorrect backup restore action or calibration action.
There is already a tare value active. Delete the old tare first.
The preset tare value entered is not valid.
The input is not valid.
Something is wrong in the calibration. Perform a new calibration after
doing a reset.
Indicator power is so low that proper functioning of the system is no
longer guaranteed. The system will automatically switch off after 10
seconds.
Reboot or reset is being performed.
Bluetooth master module not installed or defect.