5.3 Error messages
Error message
Solution
Weight not stable
Forks overloaded
Not allowed
Out of zero range
Load cell overloaded
Negative weight
Signal too low
Cal. point too low
Bad calibration
Charge battery F1!
Charge battery F2!
Charge battery Ind.!
No signal F1
No signal F2
Bad signal F1
Bad signal F2
Not level
OIML not allowed
NTEP not allowed
OIML Cal. locked
NTEP Cal. locked
Low battery indicator
Low battery F1
Low battery F2
Load not centered
Weight needs to be stable to perform this action.
Remove weight from the forks.
The performed action is not allowed due to restrictions.
Make sure the truck is unloaded while setting a new zero.
Use other capacity load cells or load cells with less signal.
The signal at this calibration point is lower than expected. Increase the
weight.
Not enough signal difference to make a reliable calculation.
Make sure this calibration point is higher than previous one.
No calibration has been saved. Perform a new calibration.
Battery of fork module 1 is critically low and needs to be charged. You will
risk losing data or not being able to perform a weighing if ignored.
Battery of fork module 2 is critically low and needs to be charged. You will
risk losing data or not being able to perform a weighing if ignored.
Battery of indicator is critically low and needs to be charged. You will risk
losing data or not being able to perform a weighing if ignored.
No communication possible between fork module 1 and indicator because
of signal loss.
No communication possible between fork module 2 and indicator because
of signal loss.
Try to improve communication by replacing the indicator or shifting fork 1.
Try to improve communication by replacing the indicator or shifting fork 2.
Forks are tilted too far to get an accurate reading. Make sure the mast of
the truck is within vertical tolerance.
Performed action is not allowed because of OIML restrictions.
Performed action is not allowed because of NTEP restrictions.
Calibration or parameter settings are locked due to OIML restrictions.
Contact your dealer/supplier.
Calibration or parameter settings are locked due to NTEP restrictions.
Contact your dealer/supplier.
Warning that the battery of the indicator is running low. You might consider
charging the battery.
Warning that the battery of fork module 1 is running low. You might
consider charging the battery.
Warning that the battery of fork module 2 is running low. You might
consider charging the battery.
Centre point of gravity of the load is too far off which could cause
dangerous situations and inaccurate readings. Replace the load in
opposite position of the gravity point.
Error messages will be displayed in the message line (21).