• The device’s body should be cleaned with a dry or slightly wet cloth. During cleaning the device cannot
be connected to the mains. Do not immerse in water.
• Store it in a clean and dry place. Store out of reach of children. Protect against dust, humidity, and
mechanical damage.
• Transport in the original packaging, protecting against dust, humidity, and mechanical damage.
• WARNING! Before switching the device on, make sure that the power characteristics comply with the
parameters on the nameplate.
• Despite proper use of the device and following all safety guidelines, some specific residual risks cannot
be completely eliminated.
3. Instruction for use:
1. Be sure the humidifier is OFF and disconnected from the electrical outlet.
2. Place the humidifier on a flat surface, about 60cm away from the floor and 10cm away from the wall.
We
recommend you not to place the humidifier on important furniture.
3. Filling the water tank instructions
-Remove the water tank by holding the handle and lifting straight upward.
-Twist off the tank cap located on the bottom of the tank by turning counter clockwise and fill the water
tank
with cool, fresh water. DO NOT FILL WITH WARM WATER AS THIS MAY CAUSE LEAKING.
-After filling the tank, replace the tank cap by firmly turning clockwise and then replace the water tank on
the base. The tank will immediately begin to empty into the base.
4. Plug the power cord into a rated electrical outlet.
4. Cleaning and maintenance:
In case when the water is hard which means water contains too much calcium and magnesium, they can
cause “white powder” problem and give heavy scales on the surface of water basin, transducer and inner
surface of the water tank. Scales on the surface of transducer will unable the unit work properly.
We recommend:
1) Use cold boiled water or distilled water.
2) Clean the transducer, water tank and basin unit every week.
3) Change the water in water tank more often to keep it fresh.
4) Make sure to pull out the water from the water tank and dry the water basin before you store the unit
unused for a long period of time.
5) Clean the whole unit, and make sure that all parts of the unit are dried completely before unused for
longer
period of time.
6) Do not use the chemical for cleaning.
How to clean the transducer:
1) Put 5-10 drops of cleaning abluent on the surface of the transducer, wait for 2-5 minutes;
2) Brush out the scale on the surface.
3) Rinse the transducer with clean water.
How to clean the basin unit:
1) Cleaning the water basin with soft cloth and the cleaning abluent if there is scale in it.
2) If the scale is covered on the security switch, drop the cleaning abluent on the scale and clean it out
with
the brush.
3) Rinsing the water basin with clean water.