XI. POPULAR DEFECTS
PROBLEM
CAUSE
SOLUTION
The air-conditioner does not
switch on.
No power supply
Plug the air-conditioner.
The water tank overflow indicator
is on
Empty the water tank
The air-conditioner restarts
Direct sunlight
Cover the windows
The doors and windows are open,
multiple heat sources in the room
Close the doors and windows,
remove the heat sources from the
room
Soiled filter
Clean or remove the filter
Air inlet or outlet is obstructed
Remove the obstacles
Noisy operation
The air-conditioner is not level
Put the air-conditioner on an even
surface to prevent vibrations
The compressor does not operate
Active compressor protection
This should not last over 3 minutes
Restart the air-conditioner
If the above-mentioned advice does not solve the problem, contact the repair service.
Technical parameters
Voltage
220-240 V
Frequency
50 Hz
Refrigerant/weight
410A/370g
The remote control
Power supplied 2 x AA (3V d.c.)
PM-9500
PM-9500S
PM-8500
PM-8500S
Description
Symbol
Unit
Value
Value
Rated cooling efficiency
P rated
Cooling
kW
2,6
2,0
Rated heating efficiency
P rated
Heating
kW
-
-
Nominal power consumption
Cooling
P EER
kW
1
0,9
Nominal power consumption
Heating
P COP
kW
-
-
Rated energy efficiency ratio
EERd
-
2,6
2,6
Rated efficiency ratio
COPd
-
-
-
Power consumed with the thermostat off
P TO
W
131,1
131,1
Power consumption in standby mode
P SB
W
1
1
Power consumption of single-/dual-channel
air-conditioners
- Cooling
- Heating
DD: Q DD
SD: Q SD
DD: kWh/h
SD: kWh/h
0,9
-
0,9
-
Sound power
L WA
dB (A)
64
64
Global Warming Potential
GWP
kg CO
2
equivalents
1975
1975
Further information can be obtained from
RAVANSON LTD. Sp. z o.o.
ul. Mazowiecka 6, 09-100 Płońsk
The manufacturer reserves the right to introduce technical modifications!
Summary of Contents for PM-8500
Page 19: ...RUS Ravanson I 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...
Page 20: ...17 18 19 24 20 21 ON OFF 22 R410a R410a II III C 1 2 3 4 5 6 7 8 9 10 11...
Page 21: ...B A 50 IV 1 2 B...
Page 22: ...C D E 3 C D E V PM 8500S PM 9500S PM 8500 PM 9500 3 7 5 4 6 2 1...
Page 25: ...1 2 3 4 X XI 3 220 240 50 410A 370 2 xAA 3V d c...