Long pressing of the button No. 2 on the combined control unit (until the LED permanently lights up) initiates

 air 

massage system drying out. 

This activates delayed start of the system drying-out. The delayed start may be 

cancelled after activation by short pressing of the respective button. Twenty minutes after the button has been 

pressed the air blower turns on for about 3 minutes, which blows air to the nozzles installed on the bathtub 

bottom and thus forcing out the water from the mains. Long pressing of the button is a protection element against 

accidental pressing of the button. This function may be activated only provided the bathtub is empty. 

The sublevel air massage system lighting 

is activated by long pressing of the button No. 3 on the combined 

control unit (until the LED permanently lights up). Pressing the button twice activates lighting pulsation. The light 

regularly goes on and out in preset time intervals in this regime. Pressing the button for the third time turns off the 

light. The button LED goes out. 

The chromotherapy feature 

is controlled by the button No. 3. Pressing the button switches on smooth blending 

of the light spectrum and a red LED diode will come on. Pressing this button one more time switches on the white 

light. Pressing the button for the third time switches off the chromotherapy and the LED diode will switch off as well. 

Pressing and holding the button No. 3 when the light fixture is on switches on step colour blending. By releasing 

the button the step colour blending stops at the present colour.

LED lights by the button symbols (diodes) signal the operation of the respective elements and functions.

If the water level is not sufficient, the system cannot be turn on due to the water-level sensor. If the water falls 

below the level required or after 20 minutes of operation, the system automatically switches itself off.

The YOU DUO Hydro/Air and YOU PLUS Hydro/Air systems are equipped with a water-level sensor (capacity 

sensor), so the system cannot be switched off if the water is bellow the level. This sensor is also connected 

to  the  water  filling  function  and  the  delayed-start  system  drying-out  function.  The  water-level  sensor  may 

 

be activated also if the massage system is not used, e.g. when bathing children, when cleaning and washing the 

bathtub, or when the sensor is covered by a towel or a bathrobe. The sensor is activated by the above-mentioned 

manners provided the bathtub (system) is powered. Accidental situation of non-standard sensor activation may 

be anticipated by disconnecting the system from the power supply by the two-phase switch, when the massage 

system is not used. The respective switch must be used in accordance to the document “Construction readiness 

for YOU acrylate bathtub with massage system YOU PLUS, YOU DUO” in each electrical installation connection 

for the massage bathtub.

If the bathtub is disconnected from the power supply for a long period of time, we recommend observing the tips 

in the CLEANING AND MAINTENANCE section.

Filling the bathtub with water  

water level signalization

Lights   

switch on / pulsation / switch off

Chromotherapy 

blending / stop / white light / switch off

Air massage system  

drying out  activation

Hydro massage  

switch on / pulsation / switch off

Air massage control  

-  intensity increase

Air massage  

switch on / pulsation / switch off

Air massage control  

-  intensity decrease

Seznam symbolů tlačítek a signalizace

Summary of Contents for YOU DUO Hydro/Air

Page 1: ...MASSAGE SYSTEMS YOU PLUS Hydro Air YOU DUO Hydro Air GUARANTEE CERTIFICATE USER MANUAL...

Page 2: ...2...

Page 3: ...STOMER GUARANTEE CUSTOMER GUARANTEE CUSTOMER GUARANTEE CUSTOMER GUARANTEE Part A TYPE OF HMS DATE OF SALE SALES DOCUMENT NUMBER DATE OF INSTALLATION PRODUCT NUMBER NAME AND SIZE OF TUB DEALER AUTHORIZ...

Page 4: ...e assembly setup and manufacturer s instructions 4 The guarantee does not extend to the parts and components that could be damaged by improper use of the product and non adherence to recommended opera...

Page 5: ...TEE CUSTOMER GUARANTEE MANUFACTURER S GUARANTEE Part B TYPE OF HMS DATE OF SALE SALES DOCUMENT NUMBER DATE OF INSTALLATION PRODUCT NUMBER NAME AND SIZE OF TUB DEALER AUTHORIZED SERVICE SIGNATURE STAMP...

Page 6: ...ible for damages caused by the unprofessional installation of the hydromassage system I hereby confirm that I have read and understood the terms of the guarantee the service instructions and all parti...

Page 7: ...n automatically in approximately 30 minutes Before use Run a sufficient amount of water into the tub first cold and then warm Turn on the blower and if the system allows choose the intensity of the ai...

Page 8: ...egulating the amount of air intake into the hydromassage jets with the help of a dial regulator pictures 2 and 3 First set the regulating dial to the minimum and then it can be raised to the maximum o...

Page 9: ...YOU PLUS Hydro Air and YOU DUO Hydro Air SYSTEMS Set the water temperature prior to filling of the bathtub and open the tap on the respective faucet The button No 1 on the combined control unit on the...

Page 10: ...peration of the respective elements and functions If the water level is not sufficient the system cannot be turn on due to the water level sensor If the water falls below the level required or after 2...

Page 11: ...for approximately 0 5 minutes so the disinfectant mixes with the water Then leave the disinfectant to function for 10 15 minutes Empty the bathtub and fill it with clean water and turn on and off the...

Page 12: ...esting all components and functions of the bathtub Demonstration on maintenance and service of the massage system Sealing the gap between the tub and the bathroom wall Final setting of the front cover...

Page 13: ...ontrol of connections for leaks ELECTRICAL Control of internal connections Visual inspection Control of connections cable clamps and cross section of the conductor wire Control of labels and seals of...

Page 14: ...14 Date reported RECORD OF MAINTENANCE AND REPAIRS DONE BY AN AUTHORIZED SERVICE DEALER Date of repair Description of repairs and replaced components Name of serviceman Signature stamps...

Page 15: ......

Page 16: ...427 111 fax 420 318 427 269 420 318 427 278 e mail info ravak cz www ravak com The manufacturer reserves the right to change the price technical parameters or other facts without a prior notice and sh...

Reviews: