When are calibrated the rear
sensors for ALL models (step 7/8),
it is necessary put Front sensors in
correspondence, in order that the
data transmission to the cabinet
pass through these ones.
If the Aligner is a 6 CCD system
(TD5060WD or TD1760WS), in step
7/8, it is necessary to press the key
F2 in order to disable the TRL/TRR
calibration (these sensors are
unprovided of TRL/TRR).
The related displays will disappears.
Figure 31
Legend of the Figure 31:
1 - Measuring heads on actual calibration step
2 - Actual calibration step
3 - Calibration steps already acquired
4 - Angles calibrated in this step with tolerance reading
5 - Value of the angle actually reading
6 - Graphic description of the measuring heads positioning on the calibration stand
7-
Keys used to put into execution the calibration step (F5 or the central key on the
measuring head); It is displayed or blinks when it possible to press it
Press F5 to establish the new calibration and press F4 to proceed step by step.
ATTENTION: The sensors of the WIRED models (WD) have to be connected only if
front (the transmission of rear ones pass through the front ones).
The sensors of the WIRELESS models (WS) have NOT never be connected.
Figure 32