![Ravaglioli RAVTD5040WD Series Service Manual Download Page 18](http://html1.mh-extra.com/html/ravaglioli/ravtd5040wd-series/ravtd5040wd-series_service-manual_3828823018.webp)
SERVICE
MANUAL
RAVAGLIOLI S.p.A.
RAVTD5040WD / 5060WD / 5080WD
RAVTD5080WS - RAVTD1760WS/1780WS
RAVTD1850WS - RAVTD2200WS
Code R0184 - rev.1.2
(01/2011)
Page 16/22
Ravaglioli S.p.A. -
Via I° Maggio, n° 3 (Frazione di Pontecchio Marconi)
40037 Sasso Marconi (Bologna - Italy)
Tel. 051/ 67.81.511 – Fax 051/ 84.64.67 e-mail: [email protected]
Starting from the initial page of the
program, using the key F2/F3 select the
"Additional features" option and confirm by
key F4.
Figure 26
Using the key F2/F3 select the
"Calibration" option and confirm by key F4.
Enter the required password to access the
calibration phase:
“F8; F7; F6; F8”
Figure 27
Using the key F2/F3, select the "Measuring
Head" calibration option and confirm by
means of key F4.
Figure 28
If required press F3 to enter the serial
number for the sensor heads so the report
eventually printed out will report such
numbers.
Enter eventually also the serial number of
tool and operator name.
Proceed confirming by key F4.
Figure 29