10.2 Preliminary Operations
10.2.1 Vehicle Check Preliminary Operations
Before starting the check of vehicle geometrical alignment, the following checks shall be
carried out:
Check and, if necessary, eliminate any clearance
on
suspensions
and
on
steering
linkage
Check and, if necessary, eliminate any hard spot or yielding of suspension spring parts.
Adjust tyre pressure to the values specified by the manufacturer.
Position and distribute any load envisaged by the manufacturer.
10.2.2 Measurement Preliminary Operations
Before proceeding with the selection of the page showing the technical data of the vehicle (see
par. 10.4 on page 27), you can start preparing the vehicle for measuring as described below:
-
Properly place the vehicle with the front wheels on the rotating plates
-
Fit clamps with the four targets onto wheels
-
Connect and switch on (*) the 2 measuring heads on lift edges (see Figure 1)
-
Lock rotating plates
Figure 19
DETECTOR
KEYPAD
PC KEYPAD
DESCRIPTION
It goes back to previous page
It continues on next page
(Selection of Make and Model)
(par.10.3 on page 25)
(*)
It is recommended to mount the clamps with the targets and switch on the 2 measuring
heads already in the preliminary stage, to enable the system to recognise and "connect" the 4
targets located on the wheels.
The time taken by the following phase for selecting make and model and for displaying
technical data is therefore used by the system also for the recognition and optimisation of the
4 targets.
(**)
In this phase, the pictures showing the 2 batteries of the measuring heads are displayed
with the relevant residual charge %. In the case of models which do not feature a battery and
are therefore powered by cable, or when the recharge cable is connected, the charge % will
always show 99%.
% RH/LH
measuring heads
battery charge
See note (**)
Target recognition
status. Note (***)