3.3 Managing PC
Software is installed on managing PC (personal computer), positioned inside cabin.
EPIA managing PC M830 features:
Processor VIA Nano 1.3GHz.
RAM 1 Gb;
Smart card reader
6 USB; 1 LAN Ethernet 10/100Mb;
Windows XP Embedded Standard 2009™ operating system, English version
1366x768 Pixels HD Ready video output
Hard Disk
≥
160 Gb
The model RAVTD3000 can be equipped with the EPIA M830 PC described above with
keyboard and a 19” Monitor or with a Laptop PC with a 15.6” screen, a 2.0GHz processor and
2 GB RAM – O.S. Windows 7™ in English, 1366x768 Pixels and HD
≥
250 GB
3.4 MEASURING HEADS
The measuring heads of the RAVTD3000ATS/ RAVTD3000NRC/ RAVTD3000HP
/RAVTD3000 do not need any cable or cord connection for angle measurement or data
transmission.
Detecting units consist of 2 megapixel cameras for each measuring head. Each camera
features a set of high efficiency infrared LED's, used to light the 3D targets fitted on the
wheels of the vehicle.
Measuring heads communicate directly with the cabin. Data are transmitted VIA RADIO
through modules
located inside heads and cabin.
Characteristic angles of both axles of the vehicle are controlled and compensated by 4 CCD
sensors and 2 electronic inclinometers located inside the two measuring heads.
Data transmission among infrared measuring heads is effective also under critical lighting
conditions.
In models RAVTD3000ATS.B; RAVTD3000NRC.B; RAVTD3000HP.B, RAVTD3000.B, power is
supplied by rechargeable 12V long-lasting batteries. Batteries are recharged when they are
inserted into the recharge supports located on the cabin (see par. 3.1).
WARNING: always switch measuring heads off upon removing and/or inserting the batteries;
manual switch-off is carried out by pressing simultaneously the most external red and green
buttons (see par. 3.4.2).
In models RAVTD3000ATS; RAVTD3000NRC; RAVTD3000HP; RAVTD3000 power is supplied
by the special cables coming from the cabin, which supply the 12V needed for operating the
heads (see 3.4.1).
Such cables can be used in battery operated models as an emergency power unit or for
recharging the batteries without removing them from their housing.
For measuring heads with rechargeable batteries, power supply and consumption data are
the following: