15.2 Machine calibration
Press the button
(
Fig. 56 ref. 2
) to display the
following screen page on monitor:
1
2
3
KEY
1 – Mandrel “Ø” calibration
2 – Weight measurement sensors calibration
3 – Gauge calibration
15.2.1 Mandrel “Ø” calibration
Press the button
to display the following screen
page on the monitor:
After making sure that the mandrel is unloaded (no
wheel or mounted accessories) and in the case of closed
pneumatic mandrel, press the button
and close
the guard. The spindle will rotate for a few minutes
until you see the screen below:
- Set the size of the rim on the mandrel using the
distance-diameter caliper arm and the external data
gauge (if present) or manual caliper.
- Press the button
and close the guard to the
perform the 1st spin of the wheel without weights.
- At the end, on the monitor will appear the following
screen, saying that you should apply a weight of 100
g to the "12 o'clock" outer rim.
At this point the machine has all its measuring fields.
Press button
to return to calibrations screen
page.
15.2.2 Weight measurement sensors calibra-
tion
ASSEMBLE A BALANCED WHEEL
ON THE SPINDLE AND PERFORM
THE SPINDLE Ø CALIBRATION
PROCEDURE DESCRIBED IN PAR.
15.2.1 (WITH WHEEL MOUNTED).
- Press on the button
to display the following
screen page:
1297-M007-1_R
G3.140R - GP3.140R - G3.140RS - GP3.140RS