Press the brake pedal and fit the adhesive weight inside
pliers as shown in
Fig. 50
.
Fit the adhesive weight in the
pliers of the gauge rod
Fig. 50
Pull out the gauge rod until the arrows (
Fig. 49 ref. 6
)
turn green.
At the end of the procedure, the wheel balancing condi-
tions can be checked by performing a trial spin.
The ECO-WEIGHT procedure has now been completed.
Fig. 51
Fit weight on the position where
pliers touches the wheel
1
2
3
4 5
6
KEY
1 – Only weight to be fitted
2 – Last program and last values used for the spin
3 – Residual dynamic unbalance value (if the value
is blue it is not to carry out ECO-WEIGHT
procedure)
4 – Static unbalance value (if the value is blue it
is not to carry out ECO-WEIGHT procedure)
5 – Residual dynamic unbalance value (if the value
is blue it is not to carry out ECO-WEIGHT
procedure)
6 – Arrows indicating the weight fitting point with
distance-diameter caliper arm
Press button
to select such procedure and bring
automatically the wheel into weight fitting position.
Fig. 49