background image

installation

Step 12. 

Connect the power source 

and verily the pilot lamp, located by the power switch on the

Central Control Assembly, remains off.

Step 13. Place the power switch to the ON position (up) and verily the 

pilot lamp lights. 

Note:

Other lamps may also be seen to illuminate within the TC4001.

Step 14. Place the 

power switch in 

the 

OFF 

position and verify all illuminated Iamps  go out.

Step 15. Install a modular connector at a convenient place in the cabinet and connect the “T” and 

“R”

twisted pair to physical number 5 of LLM 0 (TC4150)  located in the TC4001 and the Black
and Yellow twisted 

pair 

to the 

LCD 1 

pins on the 

MI0 (VC7166),  as 

shown in the following

figure.

LLM Physical

Number 5 MI0 LCD 1

TR

+-

Ye1

Modular

Connector

NOTE: These connections can be paralled  for connecting another phone, if necessary.

Step 16.

Step 17.

Connect 

a display phone 

to the modular connector installed in Step 15.

Place the power switch to the ON position and verily the display shows the message:

Step 18. Lift 

the receiver 

of the display phone and verify dial tone is received, then place the phone

back on hook.

Step 19. If Central Office or PBX trunks are installed or if there are any lines which leave the building,

ensure lightning protection is installed on each (see drawing KM0714).

© 1989  R&and-Borg Corporation (Orig. 10/88;  Rev. l/89)

Page 5 of 20

Summary of Contents for Telecenter IV

Page 1: ...k form 17 Introduction This manual provides instructions for installing and testing a Telecenter IV Except for the procedure covering initial system installation and checkout procedures for installing...

Page 2: ...er equipment is adjudged to be operating properly but the problem still exists contact the telephone company Reconnect the phone system only after determining that this equipment is not the source of...

Page 3: ...peaker lines an interconnect block with 50 pin Amphenol connectors mounted on ply wood is recommended to allow maximum ease of system maintenance and growth Step 6 If an interconnect block with connec...

Page 4: ......

Page 5: ...the Black and Yellow twisted pair to the LCD 1 pins on the MI0 VC7166 as shown in the following figure LLM Physical Number 5 MI0 LCD 1 TR Ye1 Modular Connector NOTE These connections can be paralled...

Page 6: ...s in the system Refer to the column marked PHYS in the table below for the range of physical number associated with each LLM 0 means the switch is down 1 means the switch is up Step 4 If setting must...

Page 7: ...C Sl and S2 terminals are bussed to the MI0 via a shielded cable Phone SC Sl and S2 terminals are bussed to one LLM line via a twisted pair Locate the DIP switch next to the ribbon cable connector on...

Page 8: ...to 2 inches for each cable and 8 16 inches for boards to allow ease of module removal test and repair On each module ensure the physical numbers supported are clearly identified Wire wrap around each...

Page 9: ......

Page 10: ...nabled to the display test phone Also refer to the Troubleshooting Section for information on the 73 I O Diagnostic and Computer Aided Diagnostics These tests bypass programming and operate directly o...

Page 11: ...ion described below Refer to Drawing KM0674 for wiring information Wire Graphics 1 to the first GAM module in one chain to indicate Call ins Wire Graphics 2 to a the first GAM module in a second modul...

Page 12: ...not in the privacy mode Verify a talk and listen path exists through the speaker Verify Call ins can be produced in the following three ways The type of call in produced depends on programming but can...

Page 13: ...stall Repeater Amplifier Power Supply Chassis and Modules as detailed on KM0716 Ensure the power supply is properly grounded to minimize crosstalk and digital noise on the line Avoid setting the ampli...

Page 14: ......

Page 15: ...eriod causing quicker timeout and ring stop detection This delay is most noticeable when using the TCIV built in Night Answer to pick up a call from a key phone Step 11 Install a Ring Trip Adapter bet...

Page 16: ...tural Number of the interconnect line under test If single digit dialing interferes with dialing the architectural number it may be temporar ily defeated refer to the Programming Section The CO LED on...

Page 17: ...the DIP switches on each LLM and SC board must be set to provide the proper identifica tion for recognition by system software bers and cannot 17 18 19 20 21 22 23 24 25 SCC25 TC4120 type speaker cont...