Spreading operation with the QUANTRON-A control unit
93
5
5.5
Spreading in the MAN km/h operating mode
If there is no forward speed signal, the MAN km/h operating mode is active.
1.
Switch on the QUANTRON-A control unit.
2.
Open the
Machine settings > AUTO/MAN mode
menu.
3.
Select
MAN km/h
in the menu.
4.
Enter the forward speed.
5.
Press
OK
.
6.
Configure the fertiliser settings:
Application rate (kg/ha)
Working width (m)
7.
Insert fertiliser.
8.
Carry out a calibration to determine the flow factor
or
Obtain the flow factor from the fertiliser chart.
9.
Enter the flow factor manually.
10.
Press the
Start/Stop
key.
The spreading starts.
NOTICE
In order to achieve an optimum spreading result in the MAN km/h operating
mode, a calibration is to be carried out before starting the spreading.
NOTICE
Always observe the set speed during spreading.