7.1
Adjusting the application rate
The spreading quantity is adjusted though the metering slide opening.
Figure 7.1:
Scale for the adjustment of the spreading quantity
For this purpose, move the metering slide control lever to the position you have
previously found in the fertiliser chart. This is the stopper position to which the
metering slide control lever is moved mechanically prior to the spreading drive.
Moving the lever to the right, in the direction of higher values, opens the me-
tering slide.
Moving the lever to the left, in the direction of lower values, closes the meter-
ing slide.
n
WARNING
Risk of crushing and shearing in the area of the spreading
quantity adjustment!
Adjusting the metering slide may lead to severe injury of the fingers.
Never put your fingers in the movement direction of the
metering slide control lever.
[1]
Scale for the spreading quantity
[2]
Stopper
[3]
Metering slide control lever
n
CAUTION
Material damage caused by an insufficient metering slide
opening
Insufficient opening of the metering slide can cause blockages
and can damage the spreading material. Agitator wear increases.
Always select an adequate opening for the metering slide,
at which the spreading material flows out in an unob-
structed manner.