Service manual
AXIS H-EMC/ AXIS H-EMC + W
Implement ECU software update as of
SW 2.08.00
Rauch Landmaschinenfabrik GmbH
+49 (0)7221/985-250 [email protected]
Page
12
of
16
Update SW
2.08.00
27/08/14
Chapter 410
Menu => System/test => Service => code
3354
Page 1
Machine options
(compare to the settings of chapter 3)
Machine options, page 1
RAUCH
=> selection of Rauch or Kuhn logo
(activated after restart)
AXIS 50
=> selection of Axis 50 or Axis 30
Caution
: Important, since there are different
parameters for AXIS 50 or AXIS 30
Quantity factor
=0
Actuator type
=> RH03
Level sensor
=> activate if mounted
Weigh cell
=> activate if mounted
Machine options, page 2
S/N
=> here, the serial number of the
spreader must be indicated.
SC type
=> section control calculation
FAG
=> for spreaders with FAG sensor
only
TC rate buf
=> smoothing of volume
stipulations by rate controller