3
Attachment and installation
3.1
Tractor requirements
Before installing the machine control unit, ensure that your tractor meets the following requirements:
•
A minimum voltage of
11 V
must
always
be guaranteed, even if multiple loads are connected
simultaneously (e.g., air conditioning system, lights)
•
Oil supply of metering units: at least 30 l/min per p = 180 bar, single-acting or double-acting valve
(depending on equipment),
•
PTO speed can be adjusted to 1,000 rpm and must be maintained (basic requirement for a
correct metering quantity).
On tractors without load-switchable transmission, the forward speed must be selected by
using the correct gear ratio in such a way that it corresponds to a PTO speed of
1,000 rpm
.
•
9-pin socket (ISO 11783) located at the rear of the tractor, for connecting the machine control unit
to the ISOBUS
•
9-pin terminal plug (ISO 11783) for connecting an ISOBUS terminal to the ISOBUS
The power supply of the machine control unit is implemented via the 9-pin ISOBUS socket at the rear
of the tractor.
If the tractor is not equipped with a 9-pin socket at the rear, a tractor assembly set including a 9-pin
socket for the tractor (ISO 11783) and a forward speed sensor may be purchased additionally as
special equipment.
•
The tractor has to provide the speed signal to the ISOBUS.
Check with your dealer that your tractor is equipped with the required connections and sockets.
•
Due to the numerous configurations of tractor/machine/terminal, please contact your dealer
for selecting the correct connection.
3.2
Connections, sockets
3.2.1
Power supply
The power supply of the machine control unit is implemented via the 9-pin socket at the rear of the
tractor.
3. Attachment and installation
AERO ISOBUS
5903001
17