4-4-8 Voltage regulating rectifier
Test the continuity of each pair of wires
The insulation resistance of each line shall be
≥ 20 mΩ
After confirming that the parts are not damaged through above inspections, connect all wiring
harnesses and detect the output voltage. As the detection requires starting the engine, this
operation will be dangerous. Non-professional personnel are not allowed to do the detection.
No load detection:
Charging coil (output line and
grounding)
Voltage regulator (input line
and output -)
≦
36 V
14.4±0.5 V
Load detection with battery:
No load voltage (with battery)
With load (180W needs to be
added in the figure above, and
the battery voltage ≥ 13 V)
14.4±0.5 V
12-14 V
6.5
A