background image

12 

5  Setting up the device

5  Setting up the device

5.1 

Device dimensions

with UltraVent XS 

x

y

z

Width x

Depth y

Height z

 [mm]

657    

623    

808    

 [Inch]

25 7/8

24 1/2

31 3/4

with UltraVent XS Plus 

x

y

z

Width x

Depth y

Height z

 [mm]

657    

623    

897    

 [Inch]

25 7/8

24 1/2

35 3/8

Summary of Contents for SelfCookingCenter XS UV

Page 1: ...SelfCookingCenter XS UV and UV Plus CombiMaster Plus XS UV and UV Plus Original Installation Manual...

Page 2: ...1 Device dimensions 12 5 2 Minimum distances 13 5 3 Securing the device 16 6 Electrical connection 17 6 1 General information 17 6 2 Power supply cable 19 6 3 Equipotential bonding 20 6 4 Connection...

Page 3: ...3 10 Initial start up 28 11 Maintenance 31 12 Service parts 34 12 1 UltraVent 34 12 2 UltraVent Plus 35 13 Options 36 14 Conversion tables 37 15 Declaration of conformity 39...

Page 4: ...______ ______________________________________ ______________________________________ _____________________________________ Dealer Installer Specify for all queries Appliance model Device no Set to gas...

Page 5: ...nstallation manual are competent technicians who are familiar with the process of installing and operating the device Illustrations All illustrations in this manual are examples only Deviations betwee...

Page 6: ...hat could poten tially result in serious injury or death CAUTION Possibly hazardous situation that could result in minor injury CAUTION Fire hazard CAUTION Danger of burns CAUTION Corrosive substances...

Page 7: ...tenance or cleaning of this device can result in damage injury or death as can modifications to the device Read the installation manual carefully prior to installation Device usage The device may only...

Page 8: ...h are not approved by the manufacturer void the manufacturer s warran ty and product liability Conformity Device conformity is in reference to the ove rall unit at the time of delivery The operator is...

Page 9: ...the air filter Never operate the device without the air filter When replacing the air filter please note The user may replace the air filter To replace the air filter carefully latch the new filter i...

Page 10: ...ety shoes Weight without packaging kg lbs SCC XS UV 97 214 SCC XS UV Plus 104 230 CMP XS UV 87 192 CMP XS UV Plus 94 207 ATTENTION Risk of damage to the device When transporting device ensure that air...

Page 11: ...11 4 Device transportation Transporting unit with pallet x Note required door width 880 mm 34 3 4 Transporting unit without pallet x Note required entrance width 630 mm 24 3 4...

Page 12: ...Setting up the device 5 1 Device dimensions with UltraVent XS x y z Width x Depth y Height z mm 657 623 808 Inch 25 7 8 24 1 2 31 3 4 with UltraVent XS Plus x y z Width x Depth y Height z mm 657 623 8...

Page 13: ...he left of the device becomes too high it may trigger an emergency shutdown of the device ATTENTION Device overheating may cause material dama ge Do not install fryers onto the back of the device ATTE...

Page 14: ...500 mm away from left side of the device so that service work can be performed 500mm 20 Minimum distance to ceiling min 350 mm 450mm 18 Minimum distance to other devices Minimum 350 mm distance betwee...

Page 15: ...15 5 Setting up the device Other ATTENTION Device malfunction Avoid vapor sources near the cooling air filter Moisture intake may result in device malfunc tions...

Page 16: ...The installation surface must be level clean and free of grease Unevenness across the width of the device must be no greater than 1 mm A sealant band is affixed to the underside of the device to seal...

Page 17: ...tor blue neutral conductor brown gray or black phase L1 L2 L3 ATTENTION Improper connection can cause damage to the unit e g fan motor 6 1 General information Only connect the device in accordance wit...

Page 18: ...e side panel Pull the side panel down from the device Remove the side panel Each device should have its own protected power supply line Use a fixed connection to connect each device to the power suppl...

Page 19: ...ly qualified personnel ATTENTION Non functioning device Tighten mains lead cleat Connect a supply cable of at least Type H07RN F and tighten the mains lead cleat Connect the cable according to the fol...

Page 20: ...6 4 Connection values SCC CM_P Power kW Current consumption A Fuse A 3 AC 200V 5 3 15 4 16 3 AC 230V 5 70 14 5 16 3 NAC 400V 5 7 8 5 10 3 NAC 415V 6 2 8 7 10 1 NAC 230V 5 3 22 9 25 1 NAC 240V 5 7 24...

Page 21: ...ce with EN 61770 or EN 13618 or of similar quality Take any necessary safety precautions with the water tap such as backflow preventers or CA system separators The water connection hose must comply wi...

Page 22: ...ing water pro tection pursuant to EN1717 in as delivered con dition UK only WRAS approval IRN R160 To be carried out by the installer An approved double check valve or some other no less effective bac...

Page 23: ...water treatment A B C D may be necessary if water conditions are critical Contact the local water supply company to inquire about water chloride levels Cl chlorine levels Cl2 and hardness 7 4 Selecti...

Page 24: ...stems Weak acid decarbonization H ion exchange Sodium ion exchangers as are com monly found in dishwashers are not recommen ded Phosphate metering is also not recommended due to its negative effects o...

Page 25: ...N 40 for size 60 units with a constant gradient at least 5 or 3 do not reduce pipe diameter Observe drain dimensioning requirements steam generator short term pump off rate 0 7l s Average wastewater t...

Page 26: ...26 8 Wastewater connection 250 300 mm 10 12 max 1 m 3 ft 40 mm 1 min 3 5 min 3 5 40 mm 1...

Page 27: ...ns on exhaust hoods The exhaust hood should protrude 300 500 mm over the front of the device Install the device underneath an exhaust hood if using a VarioSmoker Install a grease filter into the protr...

Page 28: ...only use containers that are easy to monitor DIN IEC 60335 2 42 The Max rack height for containers with liquid safety decal is included in the starter kit After installing the device attach the decal...

Page 29: ...tes longer To perform the self test check the hook lad ders and the air baffle to ensure they are sea ted correctly The device must be connected to water wastewater and electricity as per installation...

Page 30: ...30 10 Initial start up SCC CMP...

Page 31: ...unit from mains WARNING Danger of cutting The UV Plus ceiling can be sharp edged Wearing safety gloves Remove 2 screws at UV top and remove top cover Depending on the degree of soiling unscrew the UV...

Page 32: ...ut the pre filter Clean the pre filter in the dishwasher Exchange of HEPA filter The yellow LED indicates when the HEPA filter should be replaced Isolate unit from mains Remove the front panel Loose m...

Page 33: ...33 11 Maintenance Change HEPA filter...

Page 34: ...843 Bus cable WA44 40 05 963 Main contactor K1 K2 40 04 151 Capacitor 3 5 F 40 05 413 Capacitor 8 F 60 72 439 Motor UV WA44 M1 200 240 V 60 74 459 Mounting frame 60 73 956 Gasket 60 73 957 Cover plat...

Page 35: ...3 5 F 40 04 152 Capacitor 10 F 60 72 439 Motor UV WA44 M1 200 240 V 60 74 459 Mounting frame 60 73 956 Gasket 60 73 957 Cover plate for right hinged units 60 73 958 Cover plate for left hinged units...

Page 36: ...Article number 60 30 968 Interfaces SCC come with an Ethernet interface as part of their standard equipment An CAT 5 Ethernet cable must be used to connect to a network Connection location on the rea...

Page 37: ...mg l CaCO3 mg l Ca2 mg l 1 dH Germany 10 00 17 86 7 14 1 f France 5 60 10 0 4 00 1 e GB 8 01 14 3 5 72 1 ppm USA 0 56 1 0 0 40 1 mmol l chem cons 56 00 100 0 39 98 1 gr gal USA 9 60 64 8 17 11 6 85 1...

Page 38: ...50 0 735 20 0700 5 5 55 0 8085 22 0770 6 60 0 882 24 0840 6 5 65 0 9555 26 0910 7 70 1 029 28 0980 7 5 75 1 1025 30 1050 8 80 1 176 32 1120 8 5 85 1 2495 34 1190 9 90 1 323 36 1260 9 5 95 1 3965 38 1...

Page 39: ...39 15 Declaration of conformity 15Declaration of conformity...

Page 40: ...80 02 467 V 13 2 04 2018 RTS Dja en...