- 29 -
V02 en, SCC_WE
Fan motor SCC_WE Line
Voltage L1-L2-L3
Motor 40.03.378 - Rotor black
100 - 250V
- 550W
Motor 40.03.513 - Rotor brown
200 - 250V
- 700W
Motor 40.03.514 - Rotor brown
400 - 480V - 700W
3(N)AC 400V - 415V
61 -101 - 201
62 -102 - 202
3AC 200V - 240V
61 -101 - 201
62 -102 - 202
3AC 400V - 480V
61 - 202
NOTE: Gas units 62, 102 and 202 for countries with voltage 3AC200-240V, USA / Japan etc:
Gas units 62, 102 and 202 must be connected to L1 - L2, because the fan motor
40.03.513
is running on
200 - 250V only.
When changing the fan motor, a new motor shaft gasket must always be used!
There are 4 different fan speeds. It is possible that the motor will reduce speed independently to avoid
energy transfer by the rotating fan wheel.
The fan motor rotates clockwise - anticlockwise with a
120 second interval.
On floor units the bottom motor (with jumper) has a
60 second time lead in changing direction to the upper motor.
Blink code LED: Please refer to error messages!
On floor units with 2 motors the bottom
motor carries a jumper for bus recog-
nition. This jumper is part of the wiring
harness.
Only when the motor
is connected to mains
supply the green LED will
show and the bus signal
can be processed.
Bus
LED 100 - 240V
120 sec
120 sec
120 sec
120 sec
120 sec
120 sec
60 sec