background image

JA-3, JA3MC, JA3MC3

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

DANGER

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,

CAREFULLY FOLLOW THESE INSTRUCTIONS

TABLE OF CONTENTS

DESCRIPTION

PAGE

Installation and maintenance manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 A1

Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 A2

Shipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  A2
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 A3

Distances to respect & installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 A4

Operation / instruction for oven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 A6

Before calling for service - Answers to most frequent questions . . . . . . .

 A8

Oven maintenance and cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 A10

For more information, please call our office: . . . . . . . . . . . . . . . . . . . . . . .  A11
SECTION « B » DIMENSIONS
  JA-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

B1

  JA3MC et JA3MC3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

B4

SECTION « E » COMPONENT PARTS
 JA-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

E1

 JA3MC et JA3MC3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

E4

SECTION « G » ELECTRIC SCHEMATIC
 JA-3    120V/208V/1PH & 120V/240V/1PH (5000 WATTS). . . . . . .. .

G1

 JA-3    220V/1PH/50HZ (5000 WATTS) . . . . . . . . . . . . . . . . . . . . . . . . . G2
 JA3MC  120V/1PH  (2000 WATTS). . . . . . . . . . . . . . . . . . . . . . . . . . . .

G3

 JA3MC  120/208V/1PH (2000 WATTS) . . . . . . . . . . . . . . . . . . . . . . . .

G4

 JA3MC  120/240V/1PH (2000 WATTS) . . . . . . . . . . . . . . . . . . . . . . . .

G5

 JA3MC  220V/1PH/50HZ (2000 WATTS) . . . . . . . . . . . . . . . . . . . . . . .

G6

 JA3MC3 120/208V/1PH & 120/240V/1PH  (3000 WATTS) . . . . . . . .

G7

WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

FAMJA3.DOC

Rev. 2000/10/27

Summary of Contents for JA-3

Page 1: ...ling for service Answers to most frequent questions A8 Oven maintenance and cleaning A10 For more information please call our office A11 SECTION B DIMENSIONS JA 3 B1 JA3MC et JA3MC3 B4 SECTION E COMPONENT PARTS JA 3 E1 JA3MC et JA3MC3 E4 SECTION G ELECTRIC SCHEMATIC JA 3 120V 208V 1PH 120V 240V 1PH 5000 WATTS G1 JA 3 220V 1PH 50HZ 5000 WATTS G2 JA3MC 120V 1PH 2000 WATTS G3 JA3MC 120 208V 1PH 2000 ...

Page 2: ...e right side of the oven specifies the serial number model number number of phase amperage voltage and frequency Drawings electrical diagram and replacement part numbers are included in this manual The electrical diagram is affixed in the control panel at the back of the oven WARNING DOYON is not responsible for damages to the property or the equipment caused by personnel who is not certified by k...

Page 3: ...lified technicians and carefully crated before shipment The freight company assumes full responsibility concerning the delivery in good condition of the equipment in accepting to transport it IMPORTANT RECEPTION OF THE MERCHANDISE Make sure to verify that the received equipment is not damaged before signing the delivery receipt If a damage or a lost part is noticed write it clearly on the receipt ...

Page 4: ...E POWER RETURNS IMPORTANT INSTALLATION AND SERVICE Installation and service must be done by specialized technicians Contact a certified electrician and plumber for set up The oven must be connected to the utility and electrically grounded in conformity to the effective local regulations If these are not established the oven must be connected according to the Canadian Electrical Code CSA C22 1 XX o...

Page 5: ...st exist to allow adequate venting of hot parts C Floor 4 inches minimum D Sides of oven Do not install other than easily removable equipment for service and maintenance not closer than 4 inches E It is recommended to have a certain length 48 of electric cable between oven and wall to help gain access for service ...

Page 6: ...ameplate WARNING The electrician must make sure that the supply cable does not come in contact with the oven top which becomes hot 2 To the plumber This equipment is to be installed to comply with the applicable federal state or local plumbing codes Connect the steam system 1 4 NPT to the cold water distribution network We highly recommend a water softener to eliminate minerals in the water We sug...

Page 7: ...ht goes out and the green turns on If the light is still ON and the oven does not produce heat call for service 5 Load the oven as fast as possible to avoid letting out too much heat 6 Set the timer to the desired value and start it see TIMER adjustment on next page NOTE The timer does not shut the oven off at the end of its cycle It simply activates the buzzer 7 Wait until the product is ready Do...

Page 8: ...apacity DOORS OPENING Open the doors as little as possible This will affect the baking TIMER The oven is provided with a portable digital timer The timer can also be installed ont the bracket located under the main switch POWER FAILURE When the power comes back the oven will start automatically It is recommanded to turn off the oven to avoid that it starts without supervision ...

Page 9: ... is disengaged call for a qualified technician Uneven baking Make sure that the grills do not obstruct the airflow Do not use foil on grills The oven temperature is too high For best result cooking temperature should be around 3500 F to 3750 F To put in or take out bread pans open the door 2 5 cm and wait 5 secondes before opening the door completely Check the oven temperature by using an oven the...

Page 10: ...se steam system If not water will appear at the bottom of the oven Check if the water supply valve of the building is open Check if the water needle valve of the oven is open one eighth of a turn Just close it and open it one eighth of a turn maximum Check the solenoid valve Check the preset steam timer in the back control box Be sure to inject steam while the fan is running The steam button light...

Page 11: ...O Part number NEB201 Warning Never use cleaners such as Easy Off or equivalents in the oven After cleaning the inside of the oven apply a silicone base oven protector It avoids food from sticking to the metal We recommend and sell 316 Silicone base protector and lubricant for oven Dow Corning Part number EXS400 Clean the oven windows with products like Brasso or equivalents They are copper cleaner...

Page 12: ...on please contact our office DOYON EQUIPMENT INC 1255 rue Principale Linière Qc Canada G0M 1J0 Tel 1 418 685 3431 Canada 1 800 463 1636 U S 1 800 463 4273 FAX 1 418 685 3948 Internet www doyon qc ca E Mail doyon doyon qc ca ...

Page 13: ...SECTION B DIMENSIONS ...

Page 14: ...B1 ...

Page 15: ...B2 ...

Page 16: ...B3 ...

Page 17: ...B4 ...

Page 18: ...B5 ...

Page 19: ...B6 ...

Page 20: ...SECTION E COMPONENT PARTS ...

Page 21: ...E1 ...

Page 22: ... 3 QUA400 DOOR MAGNET 2 4 ELL650 PILOT LIGHT 1 5 ELT544B THERMOSTAT RANCO 480 F 1 AND ELT552 THERMOSTAT KNOB 550F 1 AND ELT620 THERMOSTAT BEZEL 1 6 ELI635 SWITCH 20A 130V 15A 240 V P LIGHT 1 7 PAP400 AJUSTABLE LEG 1 2 13 NC 4 8 ELB096 5A BREAKER 1 OR ELB098 2A BREAKER 220V ONLY 1 Model JA 3 View FRONT ...

Page 23: ...E3 ...

Page 24: ...Description Quantity 1 ELE110 STRAIGHT ELEMENT 208V 2500W 2 OR ELE120 STRAIGHT ELEMENT 240V 2500W 2 2 ELM934 MOTOR 240 VOLTS FOR FC16 JA3 ONLY 1 3 ELC908 HEATING CONTACTOR 1 4 ELT680 THERMOSTAT 700 F 1 Model JA 3 View BACK ...

Page 25: ...E5 ...

Page 26: ...n Quantity ON 220V 1PH 50Hz 1 ELE120 STRAIGHT ELEMENT 240V 2500W 2 2 ELM934 MOTOR 240 VOLTS FOR FC16 JA3 ONLY 1 3 ELC908 HEATING CONTACTOR 1 4 ELT715 TRANSFORMER 240 120 100VA 1 5 ELT680 THERMOSTAT 700 F 1 Model JA 3 View BACK 220V ...

Page 27: ...E7 ...

Page 28: ...4 1 2 QUP540 BLACK HANDLE 1 3 QUA400 DOOR MAGNET 2 4 ELL650 PILOT LIGHT 1 5 ELT544B THERMOSTAT RANCO 480 F 1 AND ELT552 THERMOSTAT KNOB 550F 1 AND ELT620 THERMOSTAT BEZEL 1 6 ELI635 SWITCH 20A 130V 15A 240 V P LIGHT 1 7 PAP400 AJUSTABLE LEG 1 2 13 NC 4 Model JA3MC View FRONT ...

Page 29: ...E9 ...

Page 30: ...EMENT 3000W 208 VOLTS FOR MODEL 3000 WATTS ONLY 1 OR ELE305 STRAIGHT ELEMENT 3000W 230 VOLTS FOR MODEL 3000 WATTS ONLY 1 OR ELE121 STRAIGHT ELEMENT 120V 1500W FOR MODEL 1500 WATTS ONLY 1 2 ELM957 MOTOR 1 70HP 115V 60 OR 50Hz 1 3 ELT715 TRANSFORMER 240 120 100VA 220V 1PH 50Hz ONLY 1 Model JA3MC View BACK ...

Page 31: ...SECTION G ELECTRIC SCHEMATIC ...

Page 32: ...G1 ...

Page 33: ...G2 ...

Page 34: ...G3 ...

Page 35: ...G4 ...

Page 36: ...G5 ...

Page 37: ...G6 ...

Page 38: ...G7 ...

Page 39: ...ible for having the equipment properly installed operated under normal conditions with proper supervision and to perform periodic preventive maintenance If any parts are proven defective during the period of one year from date of purchase Doyon Equipment Inc hereby guarantees to replace without charge F O B Linière Quebec Canada such part or parts Doyon Equipment Inc will pay the reasonable labor ...

Reviews: