RAG_E62SH12022208034_20120515092833_service
Common Information
------------------
Date and Time.................: 20120515092835
Startup Date and Time.........: undef
Unit type.....................: SCC_62
Energy type...................: E
Unit Serial number............: E62SH12022208034
Software version..............: SCC-05-00-10
Script version................:
SW-update Date and Time.......: undef
CPU-Board Revision............: 0506
CPU-Board Serial number.......: 25233859
CPU-Board Manufacturing date..: 2011-05-19 17:57:58
Burner Control 0 SW-version...:
Burner Control 1 SW-version...:
Language......................: german
Basic Settings
--------------
Drain Valve time0......................................: 8.7 s
Drain Valve time1......................................: 26.1 s
Gas type...............................................: 0
.......................................................:
Diagnostic-Real Time Data-Sensors act max lim Time Stamp dim
-------------------------------------------------------------------------------
Cabinet B1.............................: 26.46 307.85 350 C
Quenching B2...........................: 21.40 95.18 300 C
.......................................:
Temperature PCB........................: 35.34 81.11 80 20120514130736 C
Diagnostic-Real Time Data-Clima Status Dry Wet Combi dim__
-------------------------------------------------------------------------------
Clima Status 1-L.......................: 50066444.6882813.0194368.20 Pa
Clima Status 1-R.......................: 50063631.5785711.5992154.87 Pa
.......................................:
Clima Flap Y5..........................: CLOSE
Clima Output P1........................: 0.00 V
Clima Humidity.........................: 4.00 %
Diagnostic-Water, CJ/Care Motor/Switch Status Status Status dim__
-----------------------------------------------------------------------
Filling solenoid Y1....................: OFF
Volume Steam Generator (Norm Fill Calc): 5.48 5.57 4.38 l
CleanJet Pump M6........................: OFF
Door Contact S3........................: OFF
.......................................:
Diagnostic-Service History-SCC First time Quantity Last time
-------------------------------------------------------------------------------
Service 10.............................: 20111210215318 5 20120418135651
Service 34.............................: 20111213084631 5 20120423131943
.......................................:
Diagnostic-Service History-Gas Top-Box First time Quantity Last time
-------------------------------------------------------------------------------
14.....................................: 20120210145254
3 20120516135457
Diagnostic-Running Times-Components Value dim__
---------------------------------------------------------
Door Opening S3........................: 585
Ball Valve Openings S12................: 1381
.......................................:
Diagnostic-Running Times-Modes Value dim__
---------------------------------------------------------
Hot Air Mode...........................: 192 h