1 | MI_2091: Installation energy optimisation board
6 / 32
MI_2091_V01
MI_2091_V01
4. Install the mount with 4 board retaining clips on the SSR carrier.
5. Insert the cables of the cable trunk W32 into the energy optimisation
board and screw them together. Use the cable ends with the shorter wire
end ferrules (8 mm).
Connection
Wire colour
Connector terminal
Phase
Red
L1
Neutral conductor (neutral wire)
Blue
N
Protective conductor
Yellow/green
PE
1. Attach the cable ends with the longer wire end ferrules (12 mm). Screw the
red cable to the red wire of the contactor (1). Attach the yellow-green wire
to the yellow-green clamp (2). Attach the blue cable to the blue clamp (3).
1
2
3