9 | Waste water connection
80.06.562_IM_2-XS_ 2-S_en-INT
47 / 56
5. Put the cover back on and screw in the 2 screws.
>>
The drain pipe is connected to the unit drain water-tight.
>>
The drain pipe is connected with a constant fall of at least 5% or 3°.
>>
The cover of the connections is screwed to the unit.
Install the waste water connection with a drain on the front of the unit
If the waste water drain is installed on the front, the unit feet must be 90 mm [3
35/64 Inch] high.
The drain pipe is fixed to the adjustable foot with a mounting clamp. The fixing
for the waste water pipe is included in the equipment connection kit.
a
The adjustable foot is mounted at a height of 90 mm [3 35/64 Inch].
a
There is a drain channel with a drain sieve on the front of the unit.