9 | Waste water connection
80.06.562_IM_2-XS_ 2-S_en-INT
45 / 56
n
If you install a base with height-adjustable feet, a flexible unit drain is re-
quired. The kit with the flexible unit drain DN 40 is
not
enclosed with the
unit. The kit is available separately from the manufacturer under article
number 87.00.749.
9.2
Connect waste water drain
n
The drain connection is on the rear of the unit.
n
Diameter at unit drain: DN 40 mm
Install the waste water connection with a drain to the rear of the unit
a
The drain pipe is designed as a DN 40 mm unit drain.
a
The drain pipe corresponds to at least type PP and is resistant to high tem-
peratures.
1. Use a 90° elbow as the first pipe section for the drain pipe.
2. Close the drain pipe to the side or to the bottom.
5 %/3°