32
P:
power (kWh)
P 1:
kWh
Et:
total kWh value
P 2:
kWh
(never reset)
P 3:
kWh
Et:
kWh
By pressing the middle button, you can see the meter readings of the last 5
sessions.
Et (1):
kWh
The values can be deleted by pressing the left and
right arrow buttons at the same time.
With the middle button you can go back to the
previous screen.
Et (2):
kWh
Et (3):
kWh
Et (4):
kWh
Et (5):
kWh
CHARGER ERROR
CHARGER
In case of the charger error, you will see the error
screen with the error code. If multiple errors occur
the codes will alternate.
By error message please contact Ratio Electric for
support.
To return into the setup menu please press the
middle button for 5 seconds.
NOT READY
ERRCODE: ...............
S P E C I F I C A T I O N S
Charging System
Cable version car connector
Outlet version
Power input
Power output
Earth leakage protection
Dimensions
Housing
Weight
Environment Operating
Temperature
IEC61851, Mode 3
IEC 62196, type 1 or type 2
IEC 62196, type 2 Outlet
single-phase or 3 phase, 230V-400V, 16 A-32A
3,7 kW, 7,4 kW, 11 kW, 22 kW
AC 30mA, DC 6mA
400mm x 250mm x 105mm
PC/ABS-VO
4 kg (incl. cable)
IP54, rain-tight
-25°C to +40°C
Marking
CE