background image

1.

 Follow the previous installation 

    steps, omitting steps involving the 

    SmartView Display.

2.

 Mount the CE Elite PI Display in the 

    elevator.

3.

 Follow the wiring schematic 

    for connecting the SmartView 

    Controller with a CE Elite PI Display 

    via the RS485/422 connectors.

SmartView

Camera

To SmartView Camera

YES

To Network Switch

or 

Ethernet Extender

CE Elite PI Display

HDMI

Display  

Power

Aux  

Power

USB

Ethernet

SmartView Controller

(12v, 1A or 24v 0.5A)

YES NO

TX+

TX-

COM

RX+

RX-

NO

Wiring with Standard Network Switch

Wiring with CE Elite PI Displays

Page 7

Page 6

**Minimum CAT5E Cable**

Summary of Contents for SmartView 2100-SVC

Page 1: ...N Corporate Circle Sussex WI 53089 800 451 1460 www rathmicrotech com SmartView Visual Communication System Installation Operations Manual Made in the USA 3 Year Warranty ARE YOU TRAPPED RP850001SV Ve...

Page 2: ...to remotely assist with site preparation installation and maintenance It is our sincere hope that your experience with us has and will continue to surpass your expectations Table of Contents Pre Inst...

Page 3: ...ed HDMI cable 6 Connect the Display power output J10 to the SmartView Display power input using the provided cable Note The Controller output power J10 is only compatible with the SmartView Display No...

Page 4: ...DHCP The Software says device is offline Verify the Controller has a routed internet connection and a minimum of 5MB S Verify the Ethernet port on the Controller has an amber light and flashing green...

Page 5: ...up can be done remotely 2100 SVC Controller PoE Powered Notes 2 wire from main PoE Extender to remote PoE Extender CAT5E from communication source to main Ethernet Extender CAT5E from remote Ethernet...

Page 6: ...Extenders requires single pair 18 24ga shielded or unshielded CAT5E with RJ45 connectors required from network switch and the SmartView Controller to each Extender Main Unit Injector has LAN In intern...

Page 7: ...e SmartView Controller with a CE Elite PI Display via the RS485 422 connectors SmartView Camera To SmartView Camera YES To Network Switch or Ethernet Extender CE Elite PI Display HDMI Display Power Au...

Page 8: ...tView ID installed at your location 5 Click Submit Note If you see an error re check that a proper ID was entered 6 The IDs will be displayed on the next page 7 Once successfully linked you will see a...

Page 9: ...SmartView Camera Specifications Powered by Controller Power Requirements Active 5v 0 12A Idle 0v 0A Operating Temperature 32 F to 140 F 0 C to 60 C SmartView Display Specifications Powered by Controll...

Page 10: ...SmartView ID Location Description 10020 Elevator 1 10021 Elevator 2 Page 10 SmartView ID Location Description ID Table Appendix B Example ID Table...