background image

Phone Testing

* RATH

®

 recommends the Tower phone be tested on a regular basis to ensure proper operation.

* RATH

®

 

recommends the 12 volt battery be replaced every 2 years. (Part #: RP7700084A)

Adjusting the Volume

Page 9

Did you hear a dial tone?
Did the strobe start flashing immediately after the button was pushed?
Did the red LED become a solid light when you pushed the button?
Did the red LED flash and approximately 15-20 seconds later the called party started 

talking to you? (Delay is due to the phone telling the other party your location via the 

“Location Message”)
Can you hear the other party clearly? (If not, see “Adjust Speaker” below)
Can the other party hear you clearly? (If not, see “Adjust Microphone” below)
When the party you called hangs up, does the strobe stop?

If you have answered YES to all questions, you have successfully installed and tested 

the phone. If you answer NO to any question, proceed to the Troubleshooting Section.

Push the emergency button on the front of the Tower:

Yes

No

Volume Adjust VR1

Mic Sensitivity VR2

If the volume is too low or high, adjust it by referring to the diagram and instructions below. 

Note:

 Refer to the instructions under “Programming the Phone” to access the circuit board.

Adjusting the Microphone:

If the person you are calling reports your voice is not loud enough, increase the Microphone Sensitivity by 

adjusting VR2 a 1/4 turn clockwise (requires a small Phillips screwdriver).

Adjusting the Speaker:

If the voice of the person you call is not loud enough in the phone speaker, increase the volume by adjusting 

VR1 a 1/4 turn clockwise. 

RATH® SmartPhone

Summary of Contents for 2100-TSL

Page 1: ...RP8500080 Ver 4 10 17 36 Emergency Call Station Installation Operations Manual Emergency Tower Phone 2100 TSL Landline Solar Tower 2100 TSC Cellular Solar Tower 2100 TS9 900 MHz Solar Tower 2100 TST 2...

Page 2: ...t with site preparation installation and maintenance It is our sincere hope that your experience with us has and will continue to surpass your expectations Thank you for your business The RATH Team N5...

Page 3: ...rage Be careful of finished surfaces during transport and installation to avoid damaging the finish Installation and maintenance should only be performed by qualified electricians It is recommended th...

Page 4: ...crete pad protecting the Tower surface 2 Assemble solar strobe tube to the top of the Tower using the four bolts flat washers and lock washers The mounting hardware is in a bag attached to the solar t...

Page 5: ...to the bracket 7 Solar panel position is preset to winter months due to lower amounts of sunlight We recommend you keep it at the factory preset angle Secure solar panel bracket to solar panel in four...

Page 6: ...n Saver in the NEMA 4 enclosure see drawing below 4 Using a voltmeter check each set of terminals for Solar Battery and Load The voltage should measure between 12 6 and 13 8 volts on each set If volta...

Page 7: ...ers using 2 Way Radio are not ADA compliant the button must be pushed and held to talk and let go to listen Note Phones using 2 Way Radios are not programmable Sections in this manual on Programming t...

Page 8: ...Press 8 Enter 3 digit number in minutes Ex 2 minutes 002 Step 5 To Exit Program Mode A Press Stop for 3 seconds Step 1 To Begin Program Mode A Call into phone by dialing the number of the Tower B Afte...

Page 9: ...one below When the party you called hangs up does the strobe stop If you have answered YES to all questions you have successfully installed and tested the phone If you answer NO to any question procee...

Page 10: ...the solar terminals Using a voltmeter measure the voltage across the two terminals It should read approximately 20 volts dc on a sunny day If voltage is low or 0 the panel may be damaged Disconnect th...

Page 11: ...Page 11 Wiring Optional...