background image

Page 6

1.

 You can program the phone on-site or remotely.

 

Note:

 Cellular and 900 MHz applications cannot be remotely programmed.

2. If programming on-site, remove the face plate. Use the #10 spanner bit provided to remove the 6 security screws.

3. 

Remove the cover of the NEMA 4 enclosure by loosening the 4 corner screws.

Phone Programming

On-Site Programming:

Remote Programming:

Step 1: To Begin Program Mode

 

  A. Press 

Enter

Step 2: To Program Emergency Numbers

 

  A. Press 

1, Enter

, (phone number), 

Stop

 

      

Note:

 Press 2-5 in step 2A for emergency numbers 2-5 as needed

Step 3: To Program Location Message

 

  A. To turn on message Press 

1, 3, Enter, 2

 

  B. Press 

6, Record

 (speak message) 

Stop

 (to replay message 

Press 6, Play

)

             C. For no message Press 

1, 3, Enter, 0

Step 4: To Program Auto Disconnect Time (Default is 5 minutes, lowest interval is 1 minute)

 

  A. Press 

8, Enter,

 (3 digit number in minutes)

                 

Ex:

 2 minutes = 002

Step 5: To Exit Program Mode

             A. Press 

Stop 

for 3 seconds

Step 1: To Begin Program Mode

 

  A. Call into phone by dialing the number of the Tower

 

  B. After first simulated ring, Press 

#, #

 (Wait for 4 tones)

 

  C. Key in security code (Default is 1111) (Wait for confirmation tones) 

Step 2: To Program Emergency Numbers

 

  A. Press 

1, *, 

(Phone number), 

*, #

 (Wait for confirmation tones)

                

 Note:

 Emergency numbers (2-5) repeat step 2A pressing (2-5) as needed

Step 3: To Program Location Message

 

  A. To turn on message press 

1, 3, *, 2

 (Wait for confirmation tones)

 

  B. Press 

6, *

, (Speak message) 

#, *, #

 (Wait for confirmation tones)

 

      i. To replay message Press 

6, #

 (Wait for confirmation tones)

 

  C. For NO message Press 

1, 3, *, 0

 (Wait for confirmation tones)

Step 4: To Program Auto Disconnect Time (Default is 5 minutes, lowest interval is 1 minute)

 

  A. Press 

8, *,

 (3 digit number in minutes)

                

 Ex:

 2 minutes = 002

Step 5: To Exit Program Mode

             A. Press 

*, #, 0

 (You will hear a beep, beep) 

*, #

 (You will hear a buzz)

Keypad

Summary of Contents for 2100-TP9

Page 1: ...Ver 6 10 17 36 Emergency Call Station Installation Operations Manual Emergency Tower Phone 2100 TPL Landline 120v Tower 2100 TPC Cellular 120v Tower 2100 TP9 900 MHz 120v Tower 2100 TPT 2 Way Radio 120v Tower 2100 TPV VoIP 120v Tower 2100 TPW Wi Fi VoIP 120v Tower Made in the USA 2 Year Warranty ...

Page 2: ...ist with site preparation installation and maintenance It is our sincere hope that your experience with us has and will continue to surpass your expectations Thank you for your business The RATH Team N56W24720 N Corporate Circle Sussex WI 53089 800 451 1460 www rathcommunications com Table of Contents Description Safety Guidelines Site Preparation Items Needed Installation Communication Phone Prog...

Page 3: ...cator Powder coated steel construction inside and out Aluminum access panels powder coated inside and out Weather and vandal resistant Blue beacon and strobe Strobe turns on upon phone activation Recessed illuminated face plate Internal anchor base plate Ability to program up to 5 emergency numbers Remote or on site programmable Panels secured with security screws Torx bit provided to access panel...

Page 4: ...base next to the concrete pad 2 Open lower Access Panel 2 on back of Tower see Figure 1 3 Feed the electrical and phone wires in the conduit into the Tower base through the 4 hole 4 Align the Tower mounting holes with the four 3 4 galvanized rods and lift on to the concrete slab 5 Put a lock washer on each rod along with a nut and secure tightly Connecting the Electric Lines 1 Locate the black pos...

Page 5: ...wers using 2 Way Radio are not ADA compliant the button must be pushed and held to talk and let go to listen Note Phones using 2 Way Radios are not programmable Sections in this manual on Programming the Phone do not apply Adjusting the Volume for 2 Way Radio 1 If the volume of the Tower needs to be adjusted remove Access Panel 1 located on the back of Tower 2 Open the NEMA 4 box to access the rad...

Page 6: ...st interval is 1 minute A Press 8 Enter 3 digit number in minutes Ex 2 minutes 002 Step 5 To Exit Program Mode A Press Stop for 3 seconds Step 1 To Begin Program Mode A Call into phone by dialing the number of the Tower B After first simulated ring Press Wait for 4 tones C Key in security code Default is 1111 Wait for confirmation tones Step 2 To Program Emergency Numbers A Press 1 Phone number Wa...

Page 7: ...tested the phone If you answer NO to any question proceed to the Troubleshooting Section Push the emergency button on the front of the Tower Yes No RATH recommends the Tower be tested on a regular basis to ensure proper operation Adjusting the Volume Volume Adjust VR1 Mic Sensitivity VR2 If the volume is too low or high adjust it by referring to the diagram and instructions below Note Refer to the...

Page 8: ...t providing a disconnect signal Contact the appropriate party to make sure the disconnect signal is provided When the called party hangs up busy signal is heard through speaker Phone company or phone system is not providing a disconnect signal Operator needs to press to disconnect the call Disconnect time on phone needs to be lowered see page 6 Tower appears non functional Strobe does not flash an...

Page 9: ...Page 9 Wiring Strobe Wago Connector to front plate Phone line to communication source 1 4 5 7 8 0 9 6 3 2 Enter Record Play Pause Stop Constant Strobe 120v y r e t t a B r e m r o f s n a r T LN G ...

Reviews: