Items Needed for Installation

Item

Description

Wall Mounting Hardware

If Mounting to Wall

Pole Mount Bracket (Part # RP7700098A)

If Mounting to Pole

#1 Phillips Screwdriver
Voltage Meter
Security Torx Bit

Provided by RATH

®

Adjustable Wrench
120v Power Source
Analog Phone Line

If Using Landline

Phone Cable

If Using Landline

Installation

1.

 Remove the 12 security screws from unit. 

2.

 Remove top cap from unit.

3.

 Pull front assembly away from back unit.

4.

 Disconnect the gray Wago connector (see diagram on page 

9

).

5.

 If wall mount, mount to wall. 

6.

 If pole mount, attach unit to pole using Pole Mounting Bracket (Part # RP7700098A).

7. 

Locate the Blue (positive), Brown (negative), and Green (ground) wires coming out of the bottom of the Call 

    Station from the charging station.

8. 

Connect the electrical wires from the 120v power supply ran through conduit to the wires in the Call Station 

    using the waterproof wire nuts located on the wire.

If using 480v or 277v, an additional transformer will be installed in the Call Station and the following will need to be 

performed: 

Warning! Electrical Connection Should Be Performed by a Qualified Electrician!

480 Volt AC Supplies:

Connect H1 and H4 on the transformer to the hot and neutral of the 480 volt supply. Connect H2 and H3 

together. X2, X4 and the blue and the yellow wires on the charger should be connected to the ground lug on the 

transformer. The ground lug should be connected to an earth ground. X1 and X3 should be connected to the brown 

wire of the charger.

277 Volt AC Supplies:

Connect H1 and H6 on the transformer to the hot and neutral of the 277 volt supply. Connect H2 and H3 

together. X2, X4 and the blue and the yellow wires on the charger should be connected to the ground lug on the 

transformer. The ground lug should be connected to an earth ground. X1 and X3 should be connected to the brown 

wire of the charger.

Once the electrical is “live”, the phone needs to be programmed and tested. Reconnect the Wago connectors  that 

attach the front plate to the NEMA 4 box. If the phone will be programmed remotely, secure the front  assembly to the 

back panel and reinstall the 12 screws to the sides of the unit. If the  phone will be programmed on-site, proceed to 

the directions for “On-Site Programming”.  

Page 4

Summary of Contents for 2100-CDC

Page 1: ...k2Dawn Call Station 2100 CDL Landline Dusk2Dawn Call Station 2100 CDV VoIP Dusk2Dawn Call Station 2100 CDW Wi Fi VoIP Dusk2Dawn Call Station N56W24720 N Corporate Circle Sussex WI 53089 800 451 1460 w...

Page 2: ...o remotely assist with site preparation installation and maintenance It is our sincere hope that your experience with us has and will continue to surpass your expectations Thank you for your business...

Page 3: ...installation and with maintenance Keep all the components secure and protected during storage Be careful of finished surfaces during transport and installation to avoid damaging the finish Installatio...

Page 4: ...ing will need to be performed Warning Electrical Connection Should Be Performed by a Qualified Electrician 480 Volt AC Supplies Connect H1 and H4 on the transformer to the hot and neutral of the 480 v...

Page 5: ...h and cause permanent damage 3 Wait for the LED lights to turn on Check the SIM LED to make sure it is amber colored If it is flashing red check that the SIM card has been inserted correctly and has a...

Page 6: ...s 1 minute A Press 8 Enter 3 digit number in minutes Ex 2 minutes 002 Step 5 To Exit Program Mode A Press Stop for 3 seconds Step 1 To Begin Program Mode A Call into phone by dialing the number of the...

Page 7: ...to the Troubleshooting Section Push the emergency button on the front of the Call Station Yes No RATH recommends the Call Station be tested on a regular basis to ensure proper operation Adjusting the...

Page 8: ...t providing a disconnect signal Contact the appropriate party to make sure the disconnect signal is provided When the called party hangs up busy signal is heard through speaker Phone company or phone...

Page 9: ...robe Wago Connector to front plate 1 4 5 7 8 0 9 6 3 2 Enter Record Play Pause Stop Constant Strobe 120vac Charging Finishing Ready Dusk2Dawn Charging Station Ground Positive Negative Photocell y r e...

Reviews: