background image

AT&T
Cellular

Phone

Signal

Strength

TELEP

HON

E EN

TR

SY

STEM

HO

LD TO S

CA

N

OPE

RA

TING 

INST

 R

UCTI

ON

Us

“A

 to 

Z”

 B

utt

on

to 

Lo

ca

te

Name 

and 

Code 

Num

be

r on

 D

isplay

.

Nam

es

 a

re

 In

 Alph

ab

et

ica

l O

rder

.

To

 C

all,

 E

nte

r Co

de

 N

um

be

r o

n

Ke

yp

ad

 o

r P

re

ss

 “

Ca

ll”

 B

utto

n.

 If

Lin

e i

s B

us

y, 

Pre

ss 

“#

” o

r “

Ca

ll”

 to

Han

g Up

. Tr

y A

ga

in

.

En

te

r o

Op

en

 D

isp

la

y a

nd

 To

ne

.

1.

2.

3.

VOICE and/or DATA CELLULAR SYSTEM

The 

Voice/Data

 or 

Data Only

 Cellular System operates on DoorKing’s cellular network that is hosted on the AT&T 4G LTE network where 

available. The system provides voice communication, data communication, or both, depending on the registration plan selected on DoorKing’s 
Cellular Server website.

The 

VOICE/DATA or DATA ONLY Cellular System

 is designed to be used with:

- 1833

1834

1835

1837

, and 

1838 

entry systems.

The 

Voice/Data

 cellular system 

MUST

 be wired to the telephone entry system’s 

phone line

 (voice) and 

RS 232 connection

 (data). See page 3.

The 

Data Only

 cellular system is only wired to the telephone entry system’s 

RS 232 connection

 (data). See page 3.

The 

Voice/Data

 or 

Data Only

 cellular system will work with 

TWO

 1830 entry systems connected to it. These are designated as 

System A

 and 

System B

. See page 3 to wire 2 1830 entry systems to the cellular system.

System Operating Temperature Range:

 -10F (-23C) to 125F (52C).

DoorKing Part Number

1800-080

Copyright 2019 DoorKing

®

, Inc. All rights reserved.

120 S. Glasgow Avenue

Inglewood, California 90301 

U.S.A.

SYSTEM A

Cellular

System

Installation Steps:

1.

 Install and wire cellular system to 1830(s) (page 2 & 3).

2.

 Power up cellular system (page 4).

3.

 Register cellular system (and 1830(s)) online, this can be 

done before or after cellular system has been installed (page 4).

4.

 Test cellular system (page 4).

5.

 Program cellular system (pages 5 & 6).

6.

 Troubleshoot cellular system if necessary (page 6).

Note:

 Installation steps assume that a good cellular signal has 

been tested at installation location and the 1830 system(s) has 
already been setup and functioning including the 

master code

 

and 

multiple system programming

 if 2 1830s are being used.

Prior to Installation:

An existing cellular phone will be needed to test the signal strength of DoorKing’s 
cellular network in the desired installation location (a smart phone is preferred).

Analog modems (Dial-Up) 

DO NOT

 work on a cellular network.

 

BEFORE

 the cellular system can be installed, the installation location 

MUST BE TESTED 

for 

good cellular signal strength for reliable communication. 

TEST

 this location using an existing 

active cellular phone with 

AT&T

 phone service.

Note:

 Other cellular phone services

 

use different networks and will not work for testing signal 

strength of the cellular system.

Activate the phone near the position where you want the plastic enclosure to be installed. 3-4 
bars of signal strength should be indicated on the phone for a reliable signal. If 3-4 bars are 
not achievable in that specific location, then try moving the phone around and see if at least 
3-4 bars can be achieved and maintained in a nearby location. If a smart phone is being used, try using the browser to connect to a website to 
verify good data transfer. 

DO NOT install the enclosure in a WEAK or NO signal area.

 DoorKing offers an exterior 4G LTE cellular antenna that can 

help in areas with weak cellular service (P/N 1514-014 Sold separately). Generally, the higher the enclosure is mounted, the better the reception. 
This also helps protect against vandalism. The enclosure should be located to minimize the wire runs to 

“SYSTEM A”

 1830 telephone entry 

system. Keep the wire run between the two devices as short as possible, maximum 100 feet. This allows less chance for lightning surges or other 
electrical interference to disrupt the cellular signal. 

Keep the enclosure away from any metal.

 This can also disrupt the signal. After the 3-4 bar 

signal strength has been confirmed (and the smart phone has good browser data transfer if used for signal testing), the installation can begin.

This cellular device cannot
be used for 911 calls.

1

1800-065 Issued 1-19
Version D

Содержание 1800-080

Страница 1: ...location and the 1830 system s has already been setup and functioning including the master code and multiple system programming if 2 1830s are being used Prior to Installation An existing cellular phone will be needed to test the signal strength of DoorKing s cellular network in the desired installation location a smart phone is preferred Analog modems Dial Up DO NOT work on a cellular network BEF...

Страница 2: ...ed shall be in accordance with National Electrical Code ANSI NFPA 70 Permissible wire sizes for the terminals 12 26 AWG Type of wiring to be used on ALL external devices A Type CL2 CL2P CL2R or CL2X B Other cable with equivalent or better electrical mechanical and flammability ratings Watertight Conduit and Connectors Wire Runs Cellular System TELE PHO NE ENTR Y SYS TEM HOL D TO SCA N OPER ATING I...

Страница 3: ... telephone service and programming for TWO 1830s designated as System A and System B The telephone line is SHARED with both 1830s Each 1830 MUST be programmed for Multiple Systems see specific 1830 Installation Owner s instruction manual for more information RS 232 RS 232 RS 232 A RS 232 A LEDs External Antenna Connection RS 232 B LEDs Cellular Power Phone Jack Board Power LED RS 232 B The EARTH G...

Страница 4: ...re registering a cellular system on DoorKing s Cellular Server you will need SIM ID number located on the cellular module number is unique for each cellular module Master Code of System A Master Code of System B if connected MUST be a different master code than System A OPTION 1 Go to DKS cellular website https dksdb dksoftware com NewUserRegChoice aspx to register follow instructions on website O...

Страница 5: ...the line for programming while the 1830 will hang up If any other DTMF tones are received the cellular system will ignore them If the 1830 does not answer on the second ring the cellular system will answer on the programmed number of rings Factory default setting 5 rings Slide switch to Program 87 Master Code Beep 04 Beep 2 9 Beep number of rings before answering call Hang up Phone Slide switch ba...

Страница 6: ...LED lights on the Voice Data cellular circuit board During a data transfer the yellow Ethernet data LED should be flashing The data LED near the RJ45 cable should be flashing The RS 232 LEDs should be flashing for the proper system either A or B indicating attempted data transfer If the wrong RS 232 LEDs are flashing A and B systems are mixed up Check the 1830 baud rate setting It should be 19200b...

Страница 7: ...vice meets the government s requirements for exposure to radio waves This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency RF energy set by the Federal Communications Commission of the U S Government This device complies with FCC radiation exposure limits set forth for an uncontrolled environment Glossary for UL 294 Compliance ACCESS CONTROL SYS...

Отзывы: