    SAFETY GUIDELINE

● Installation, commissioning and maintenance of this appliance may only be undertaken by an

   authorized technician who will then be responsible for adhering to the applicable standards 

   and/or installation regulations. 

● All spare parts provided by the manufacturer must be duly installed. We are not liable for

   any damages caused by non-compliance with these instructions. 

● Sole Distributor will not provide warranty service on any product installed with unauthorized 

   components or devices.

** WARNING ** 

: The appliance must be 

EARTHED

.

● The appliance may only be used when correctly installed by authorized technician and in 

    good working order. 
● The appliance must be completely filled with water and air bubbles released inside the water

 tank before being switched on.

● The spare parts provided by the manufacturer must be installed and its wiring and piping must

 not be modified in any way. The hot water outlet and fittings may be very hot! Keep away from

 children.

● Subject to local Electrical Laws and Regulations, one of the followings may be provided

 (Provision and fixation by client):

    i. miniature circuit breaker (MCB)

ii. earth-leakage circuit breaker (ELCB)

● It is normal if water drips from the Temperature and Pressure Relief Valve (P&T Valve) while

 the water is being heated.

● The maintenance access panel of the appliance must never be opened before disconnecting the

 appliance from the main power supply.

● Do not switch on if there is a possibility that the water in the heater is frozen.
● The water inlet of this appliance shall not be connected to water inlet of any other water heating

   systems. 
● Do not allow children to play or touch with the water heater, guardian need to supervise children,

    to prevent the electrical shock or any injuries.
● This appliance is not intended to be operated by children or disabled persons alone. 

 They must be supervised by adults who are responsible for their safety. 

● This appliance is not to be used for a potable water supply. 
● If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 

 authorized technician in order to avoid a hazard.

● Check water temperature before use, the shower head should always be pointed away from 

 human before cold water is turned on. After use, turn the mixer to cold arrow and shut off.   

● Disconnect the power supply if the appliance is idle for a prolonged period. 

 The initial operation procedures must be carried out before reuse.

Summary of Contents for RWH-CT5

Page 1: ...7 Please read the operation instruction carefully before using and well keep it in a safe place for future reference Some figures in this instruction may not match with the real object just for refere...

Page 2: ......

Page 3: ...ct Information 8 4 Product Structure 8 5 Installation Instructions 9 6 Pre Installation Notice 10 11 7 Installation Diagram 12 8 Wiring Diagram 12 9 Technical Specification 13 14 10 Operating Instruct...

Page 4: ...breaker MCB ii earth leakage circuit breaker ELCB It is normal if water drips from the Temperature and Pressure Relief Valve P T Valve while the water is being heated The maintenance access panel of...

Page 5: ...5 i MCB ii ELCB...

Page 6: ...Technical Principal ISM Hot Water Injection System Rasonic s Water Heater apply a 3rd Generation patented Hot Water Injection System including Combustion Chamber with rapid burner 3kW rating operated...

Page 7: ...7 1 1 2 3 4 5 6 7 1 1 M6 6 4 1 1 1 1 ISM 3 PID PID 2 C...

Page 8: ...8 Measurements PRODUCT INFORMATION Model No RWH CT5 RWH CT7 RWH CT5 RWH CT7 Height 690mm 690mm 690 690 Depth 168mm 195mm 168 195 Width 380mm 380mm 380 380 PRODUCT STRUCTURE...

Page 9: ...hould not exceed 99 C and working pressure at 1 0MPa 10 bar Tighten and connect a drain pipe not supplied by manufacturer to the pressure and temperature relief valve Water might drip from the P T Val...

Page 10: ...afety 3 The diameter of piping should be 1 2 BSP Connect the inlet pipe blue with water supply Then connect the outlet pipes red with supply pipe leading to points of use 4 Turn on the hot water tap T...

Page 11: ...11 P T Valve 99 1 0MPa 10bar P T Valve 220 P T Valve 3 P T Valve 1 P T Valve P T Valve 2 P T Valve P T Valve 100 150 3 4...

Page 12: ...12 WIRING DIAGRAM INSTALLATION DIAGRAM 690mm 380mm 34mm 70mm 180mm 100mm 195mm Hot water outlet Water inlet G1 2 G1 2 Hanger P T Valve 60mm 190mm Cable entrance...

Page 13: ...6MPa 6Bar Maximum Pressure 220V 50Hz 3kW Rated Voltage Rated Loading 13 4 Ampere Rated Current G 1 2 Male BSP British Standard Pipe Thread Pipe Connection 75 80dg C Working Temperature Inner Tank IPX...

Page 14: ...14 RWH CT5 RWH CT7 SUS304 20 13 33 24 15 39 1 0 MPa 10Bar 0 6MPa 6Bar 220 50 3 13 4 A 1 2 75 80 IPX4 CFC...

Page 15: ...sonic s water heater to other source of water supply other than the potable water supply as the result will have no warranty to the Company Water Shortage During water shortage do not drain water from...

Page 16: ...nnection call customer service department to check thermal cutout main controller or heating element if fuse and electrical connection is normal Check if the water temperature setting is appropriate o...

Page 17: ...e must be vented slightly at regular intervals once per month to ensure proper functioning Pull the lever until the valve opens and water drains from the outlet Re close the valve If water continues t...

Page 18: ...9867 6452 Special Avowal 1 If information above has been checked our company reserves the hermeneutic power to any print errors or misunderstanding on the content 2 In case there is any inconsistency...

Page 19: ......

Page 20: ......

Reviews: