background image

16

Safety precautions

  

WARNING

Indoor unit and outdoor unit

This appliance is not intended for use by 

persons (including children) with reduced 

physical, sensory or mental capabilities, or 

lack of experience and knowledge, unless they 

have been given supervision or instruction 

concerning use of the appliance by a person 

responsible for their safety. Children should be 

supervised to ensure that they do not play with 

the appliance.
Please consult an authorised dealer or 

specialist to clean the internal parts, repair,

install, remove, disassemble and reinstall the

unit. Improper installation and handling will

cause leakage, electric shock or 

fi

 re.

Con

fi

 rm with authorised dealer or specialist on 

usage of any speci

fi

 ed refrigerant type. Using 

refrigerant type other than the speci

fi

 ed may 

cause product damage, burst and injury etc.
Do not use means to accelerate the defrosting 

process or to clean, other than those 

recommended by manufacturer.

Any un

fi

 t method or using incompatible material 

may cause product damage, burst and serious 

injury.
Do not install the unit in a potentially explosive 

or 

fl

 ammable atmosphere. 

Failure to do so could result in 

fi

 re.

Do not insert your 

fi

 ngers or other 

objects into the air conditioner indoor 

or outdoor unit, rotating parts may 

cause injury.
Do not touch the outdoor unit during lightning, it 

may cause electric shock.
Do not expose yourself directly to cold air for a 

long period to avoid excess cooling.
Do not sit or step on the unit, you may 

fall down accidentally.

Remote control

Do not allow infants and small children to play 

with the remote control to prevent them from 

accidentally swallowing the batteries.

To prevent personal injury, injury to others or property 

damage, please comply with the following: 

Incorrect operation due to failure to follow instructions 

below may cause harm or damage, the seriousness of 

which is classi

fi

 ed as below:

This appliances is not intended for accessibility by the 

general public.

WARNING

This sign warns of death 

or serious injury.

CAUTION

This sign warns of injury 

or damage to property.

The instructions to be followed are classi

fi

 ed by the 

following symbols:

This symbol denotes an action that 

is PROHIBITED.

These symbols denote actions 

COMPULSORY.

Indoor unit

Outdoor unit

Power supply

Remote control

Air inlet

Air inlet

Air inlet

Air inlet

Air outlet

Air outlet

Air outlet

Air outlet

ACXF55-28230_SS0320-1.indb   16

ACXF55-28230_SS0320-1.indb   16

21/2/2020   10:05:27 AM

21/2/2020   10:05:27 AM

Summary of Contents for RS-LE9WK

Page 1: ...e read these operating instructions thoroughly and keep them for future reference The included Installation Instructions should be kept and read by the installer before installation Remote control is...

Page 2: ...FF SET TIMER CANCEL OFF ON AIR SWING TEMP OFF ON MODE SLEEP FAN SPEED QUIET POWERFUL ECO ON OFF TIMER CANCEL AIR SWING SLEEP FAN SPEED QUIET POWERFUL ECO B A ACXF55 28230_SS0320 1 indb 2 ACXF55 28230_...

Page 3: ...8 9 10 12 13 Rasonic AAA R03 2 2 B 2 MODE DRY AUTO HEAT COOL 1 POWER 3 TEMP 16 0 C 30 0 C 60 F 86 F 10 C F ACXF55 28230_SS0320 1 indb 3 ACXF55 28230_SS0320 1 indb 3 21 2 2020 10 05 20 AM 21 2 2020 10...

Page 4: ...4 ACXF55 28230_SS0320 1 indb 4 ACXF55 28230_SS0320 1 indb 4 21 2 2020 10 05 21 AM 21 2 2020 10 05 21 AM...

Page 5: ...5 ON Ni Cd nanoe G ELCB RCD ELCB BS ACXF55 28230_SS0320 1 indb 5 ACXF55 28230_SS0320 1 indb 5 21 2 2020 10 05 21 AM 21 2 2020 10 05 21 AM...

Page 6: ...ERFUL 20 ECO FAN SPEED QUIET POWERFUL ECO POWERFUL ECO nanoe G ON OFF SET TIMER CANCEL OFF ON AIR SWING TEMP OFF ON MODE SLEEP FAN SPEED QUIET POWERFUL ECO POWER TIMER nanoe G ECO ACXF55 28230_SS0320...

Page 7: ...ANCEL 1 2 3 1 ON OFF 22 00 OFF OFF 2 3 SET ON OFF CANCEL ON OFF ON OFF SET ON OFF ON OFF POWERFUL ECO SLEEP FAN SPEED QUIET POWERFUL ECO POWERFUL QUIET FAN SPEED ACXF55 28230_SS0320 1 indb 7 ACXF55 28...

Page 8: ...F 82 F COOL DRY AUTO HEAT AUTO TIMER C F DBT WBT DBT WBT COOL 32 89 6 23 73 4 43 109 4 26 78 8 16 60 8 11 51 8 16 60 8 11 51 8 HEAT 30 86 0 24 75 2 18 64 4 16 60 8 5 23 0 6 21 2 DBT WBT ACXF55 28230_S...

Page 9: ...9 nanoe G 2 2 AUTO OFF ON nanoe G nanoe G H 99 pH 7 40 C 104 F 1 2 AUTO OFF ON nanoe G 2 1 3 4 ACXF55 28230_SS0320 1 indb 9 ACXF55 28230_SS0320 1 indb 9 21 2 2020 10 05 23 AM 21 2 2020 10 05 23 AM...

Page 10: ...10 POWER ON ON 30 TIMER 30 nanoe G COOL HEAT nanoe G nanoe G ACXF55 28230_SS0320 1 indb 10 ACXF55 28230_SS0320 1 indb 10 21 2 2020 10 05 25 AM 21 2 2020 10 05 25 AM...

Page 11: ...O OFF ON 1 2 AUTO 3 COOL 4 3 2 HEAT 5 5 OFF ON COOL HEAT 15 COOL 8 C 14 4 F HEAT 14 C 25 2 F HEAT 2 3 ACXF55 28230_SS0320 1 indb 11 ACXF55 28230_SS0320 1 indb 11 21 2 2020 10 05 25 AM 21 2 2020 10 05...

Page 12: ...5 H 26 ION H 27 H 28 1 H 30 H 31 H 32 2 H 33 H 34 H 35 H 36 H 37 H 38 H 39 H 41 H 50 H 51 H 52 H 58 H 59 H 64 H 67 nanoe H 70 H 71 H 72 H 85 H 97 H 98 H 99 F 11 F 16 F 17 F 18 F 87 F 90 PFC F 91 F 93...

Page 13: ...13 Pb ACXF55 28230_SS0320 1 indb 13 ACXF55 28230_SS0320 1 indb 13 21 2 2020 10 05 25 AM 21 2 2020 10 05 25 AM...

Page 14: ...t AAA or R03 batteries 3 Close the cover A Clock setting 1 Press and set the time Press and hold for approximately 5 seconds to show time in 12 hour am pm or 24 hour indication 2 Confirm SET 4 ON OFF...

Page 15: ...to change without notice for future improvement B Basic operation 2 Press MODE to select the desired mode DRY AUTO HEAT COOL 1 Press to start stop the operation POWER Please note that the indication i...

Page 16: ...ld result in fire Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Do not touch the outdoor unit during lightning it may caus...

Page 17: ...tended non use or During abnormally strong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosio...

Page 18: ...on the flap and fan speed will operate based on remote control setting If power failure occurs during this operation this operation will be resumes immediately after power resumes To enjoy freshness a...

Page 19: ...ted in all modes Can be cancelled by pressing the respective button again POWERFUL QUIET and FAN SPEED cannot be selected at the same time To set the timer ON OFF SET TIMER CANCEL CANCEL 1 2 3 1 Selec...

Page 20: ...L DRY mode If AUTO is set the flaps swings up down automatically In HEAT mode If AUTO is set the horizontal flap is fixed at the predetermined position Auto restart control If power is resumed after a...

Page 21: ...e to the filter surface Dry the filters thoroughly under shade away from fire or direct sunlight Replace any damaged filters Remove air filter Attach air filter Insert into the unit Indoor unit Wipe t...

Page 22: ...urs on pipes Discoloration of some plastic parts Discoloration is subject to material types used in plastic parts accelerated when exposed to heat sun light UV light or environmental factor Dust may h...

Page 23: ...ter 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F HEAT 14 C 25 2 F The units are not going to be used for a l...

Page 24: ...r outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mismatch brand code H 39 Ab...

Page 25: ...tems please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symbol bottom two symbol examples This symbol might be used in combination with...

Page 26: ...Memo ACXF55 28230_SS0320 1 indb 26 ACXF55 28230_SS0320 1 indb 26 21 2 2020 10 05 30 AM 21 2 2020 10 05 30 AM...

Page 27: ...Memo ACXF55 28230_SS0320 1 indb 27 ACXF55 28230_SS0320 1 indb 27 21 2 2020 10 05 30 AM 21 2 2020 10 05 30 AM...

Page 28: ...0 SS0320 1 Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan Website http www panasonic com Panasonic Corporation 2020 ACXF55 28230_SS0320 1 indb 28 ACXF55 28230_SS0320 1 indb 28 21 2 2020 10...

Reviews: