LD-705
"LD" Multi-Burner
12028 E. Philadelphia St. Whittier , CA 90601 U.S.A.
(562) 696-8718 FAX (562) 698-3510
[email protected] www.rasmussen.biz
GENERAL INSTALLATION INSTRUCTIONS
ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS FOR
Vented Gas Log Burner
MODELS:
LD(30, 36, 48, 60, 72, 84, 96)-N for use with Natural Gas or
LD(30, 36, 48, 60)-P for use with Propane (LP) Gas
IMPORTANT
READ THESE INSTRUCTIONS CAREFULLY BEFORE
STARTING INSTALLATION OF LOG SET.
WARNING:
Improper installation,
alteration, service or maintenance can cause
injury or property damage. Read these
instructions thoroughly before installation.
For assistance or additional information, consult
your gas log dealer, qualified installer, service
agency or gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
• If you cannot reach your gas supplier, call the
fire department.
IMPORTANT INFORMATION
THIS GAS LOG SET MUST BE INSTALLED IN A FULLY VENTED
SOLID-FUEL BURNING FIREPLACE WITH A WORKING FLUE
CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL.
The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum
Chimney Area shown below, based on a minimum chimney height of at least 8 feet. The area of the flue must not be less
than 1/10 the area of the fireplace opening.
The flue must exhaust all products of combustion.
The chimney damper must be fixed in a manner to maintain permanent free opening as outlined above at all times. To
accomplish this, install the damper clamp (provided) on the edge of the damper blade to prevent its closing, drill a hole or
holes in the damper, or remove damper completely.
The minimum size of the fireplace in which the log set is to be installed must be as follows:
MINIMUM FIREPLACE SIZE IN INCHES
LOG SET SIZE
HEIGHT
DEPTH
REAR WIDTH
FRONT WIDTH
GAS PIPING
CHIMNEY AREA
30 INCH
36 INCH
42 INCH
48 INCH
54 INCH
60 INCH
66 INCH
72 INCH
84 INCH
96 INCH
26
30
30
34
34
34
34
34
34
34
20
22
22
22
22
22
22
22
22
22
30
36
42
.
48
54
60
66
72
84
96
38
44
50
58
64
70
76
82
94
106
½” i.d.
½” i.d.
½” i.d.
3/4” i.d.
3/4” i.d.
1” i.d.
1” i.d.
1” i.d.
1” i.d.
1” i.d.
12 INCH DIAMETER
14 INCH DIAMETER
14 INCH DIAMETER
16 INCH DIAMETER
16 INCH DIAMETER
18 INCH DIAMETER
18 INCH DIAMETER
.
20 INCH DIAMETER
.
20 INCH DIAMETER
.
20 INCH DIAMETER
f i r e - p a r t s . c o m