    "LD" Multi-Burner

 

 

12028 E. Philadelphia St. Whittier , CA 90601  U.S.A. 

(562) 696-8718        FAX (562) 698-3510 

 [email protected]            www.rasmussen.biz

 

GENERAL INSTALLATION INSTRUCTIONS

 

 

ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS FOR 

Vented Gas Log Burner

 MODELS: 

LD(30, 36, 48, 60, 72, 84, 96)-N for use with Natural Gas or 

LD(30, 36, 48, 60)-P  for use with Propane (LP) Gas 

 

 

IMPORTANT

READ THESE INSTRUCTIONS CAREFULLY BEFORE 
STARTING INSTALLATION OF LOG SET.

 

 
 

WARNING:

 

Improper installation, 

 

alteration, service or maintenance can cause 
injury or property damage. Read these 
instructions thoroughly before installation.   
For assistance or additional information, consult 
your gas log dealer, qualified installer, service 
agency or gas supplier.

 

 

 

FOR YOUR SAFETY

 

Do not store or use gasoline or other flammable 
vapors and liquids in the vicinity of this or any 
other appliance.

 

FOR YOUR SAFETY

 

WHAT TO DO IF YOU SMELL GAS

     

 

• 

Do not try to light any appliance. 

 

•  Do not touch any electrical switch; do not use 

any phone in your building. 

 

•  Immediately call your gas supplier from a 

neighbors phone. Follow the gas suppliers 
instructions. 

 

•  If you cannot reach your gas supplier, call the 

fire department.

 

 
 

IMPORTANT INFORMATION

 

THIS GAS LOG SET MUST BE INSTALLED IN A FULLY VENTED 

SOLID-FUEL BURNING FIREPLACE WITH A WORKING FLUE 

CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL.

  

The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum 
Chimney Area shown below, based on a minimum chimney height of at least 8 feet. The area of the flue must not be less 
than 1/10 the area of the fireplace opening. 

The flue must exhaust all products of combustion.

 

 

The chimney damper must be fixed in a manner to maintain permanent free opening as outlined above at all times. To 
accomplish this, install the damper clamp (provided) on the edge of the damper blade to prevent its closing, drill a hole or 
holes in the damper, or remove damper completely. 

 

The minimum size of the fireplace in which the log set is to be installed must be as follows: 

 

MINIMUM FIREPLACE SIZE IN INCHES 

 

LOG SET SIZE 

 

HEIGHT 

 

DEPTH 

 

REAR WIDTH 

 

FRONT WIDTH

 

 

GAS PIPING 

 

CHIMNEY AREA 

30 INCH 
36 INCH 
42 INCH 
48 INCH 
54 INCH 
60 INCH 
66 INCH 
72 INCH 
84 INCH 
96 INCH 

26 
30 
30 
34 
34 
34 
34 
34 
34 
34 

20 
22 
22 
22 
22 
22 
22 
22 
22 
22 

30 
36 

42

.

 

48 
54 
60 
66 
72 
84 
96 

38 
44 
50 
58 
64 
70 
76 
82 
94 

106 

½” i.d. 
½” i.d. 
½” i.d. 

3/4” i.d. 
3/4” i.d. 

1” i.d. 
1” i.d. 
1” i.d. 
1” i.d. 
1” i.d. 

12 INCH DIAMETER 
14 INCH DIAMETER 
14 INCH DIAMETER 
16 INCH DIAMETER 
16 INCH DIAMETER 
18 INCH DIAMETER 

18 INCH DIAMETER

20 INCH DIAMETER

20 INCH DIAMETER

20 INCH DIAMETER

 

 

f i r e - p a r t s . c o m

Summary of Contents for LD Series

Page 1: ...IS GAS LOG SET MUST BE INSTALLED IN A FULLY VENTED SOLID FUEL BURNING FIREPLACE WITH A WORKING FLUE CONSTRUCTED OF NON COMBUSTIBLE MATERIAL The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum Chimney Area shown below based on a minimum chimney height of at least 8 feet The area of the flue must not be less than 1 10 the area of the fireplace o...

Page 2: ... system at test pressures equal to or less than 1 2 psig 3 5 kPa The area around the gas log set must be clear and free from combustible materials gasoline and any other flammable vapors and liquids Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control whi...

Page 3: ...an the venting system Once a year a qualified agency should examine and clean the venting system of your solid fuel burning fireplace GENERAL INSTALLATION INSTRUCTIONS ATTENTION READ THESE INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY REQUIRED TOOLS AND MATERIALS Screwdriver Adjustable Wrench Pipe Wrench Pipe Sealing Compound Matches PREPARATION 1 This Gas Log set must be INSTALLED IN A FULLY VENTED META...

Page 4: ... one end of the FLEXIBLE CONNECTOR TUBE C to the 1 2 FIP x 5 8 FLARE ELBOW B and wrench tighten 3 Carefully bend CONNECTOR TUBE C and connect without pipe compound to the FLARED VALVE INPUT FITTING D Wrench tighten NOTE CONNECTOR TUBE C may kink or break causing air flow noise and or leaks if bent into too small a radius 4 Turn gas supply to fireplace on 5 Test all connections for leaks with soapy...

Page 5: ...pan to enhance ember bed appearance 3 VOLCANIC ASH available separately may be sprinkled around the OUTSIDE of the BURNER PAN as a decorative effect BURNER TUBES EMBER MAGIC Figure 5 GAS BLACK VOCANIC ASH FOR LP BURNER PAN MEDIUM WHITE SAND FOR NATURAL MEDIUM MEDIUM STEP FOUR Log Placement 1 Place logs in accordance with separate Recommended Log Placement Instructions The Large Top Logs are placed...

Page 6: ...S SUPPLY VALVE and wait for burner to light See FIGURE 7 3 Adjust FIREPLACE GAS SUPPLY VALVE for desired flame height 4 Adjust front burner with attached manual valve s to provide desired ember flame effect Note The natural gas versions of LD30 and LD36 have one front burner valve LD48 and LD60 have two The propane versions of all models have fixed front burner flames The rear burners are valved f...

Page 7: ...oom if the fireplace chimney is venting properly There are only two places for the soot to go 1 up the chimney or 2 into the room The reasons for soot going into the room may include Damper not open or not open far enough Too small of a flue Too large of a fireplace opening in comparison to the flue opening 1 10 rule Obstruction in the chimney Bird nest creosote build up etc Negative room pressure...

Page 8: ...TY 1 The foregoing warranty is limited solely as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental o...