• Will produce water vapor (increase indoor humidity) which may be beneficial during the dry heating season.
Customer Responsibilities And Annual Maintenance:
•
Keep the area around the CHILLBUSTER free and clear from debris. From time to time, visually check pilot and
burner flames for proper appearance (
Figures 9 and 10
). Normal flame color should be yellow body
surrounded
by a hard blue haze.
•
The pilot, air shutters and burners must be free of lint and dirt for optimum performance. Air shutters which have
been closed or are obstructed with debris will not allow sufficient combustion air into burner. Air shutters should be
periodically cleaned of debris. Use compressed air or a soft bristle brush to clear pilot and burner(s) air intakes.
Air
shutters should not be altered from factory settings
.
"WARNING: Failure to keep the primary air opening(s)
of the burner(s)clean may result in sooting or property damage."
•
Obstructed Pilot Air Intake Ports result in an improper gas/air mixture and a weak pilot flame.
Weak pilot flame
is the NUMBER 1 SERVICE ISSUE RE NUISANCE SHUT-OFF.
Using canned compressed air , pipe cleaner or an
artist's brush, clean out the opposing Air Intake Ports located at base of Pilot (where gas supply line attaches to
pilot). (
Figure 9
)
•
Do not operate in a dirty firebox or in a previously used firebox which has not had all soot completely removed or
it's chimney flue cleaned. Previously used fireboxes must have flue and stack professionally cleaned by a chimney
sweep. Additionally, firebox walls and damper must also be thoroughly cleaned of all burn residue and soot using a
damp cloth, sponge or brush.
•
Do not operate this set with any logs other than the RASMUSSEN CHILLBUSTER Refractory Logs specifically
designed and approved for use with this Burner System.
•
Do not use with blower inserts or heat exchangers.
•
If used, glass doors must be wide open when burner is on.
•
Do not remove Rating Plate/Warning Tags. These tags serve you and any future user as an integral safety and
identification component of the CHILLBUSTER gas log heater. Removing these tags voids the warranty.\
•
WARNING:
Do not allow fans to blow directly into fireplace. Avoid any drafts that alter burner flame
patterns.
Do not place blower inside area of firebox. Ceiling fans may create drafts that alter burner flame
patterns. Sooting and improper burning may occur. Sooting can settle on household surfaces outside the
fireplace.
•
During periods of heavy use, inspect frequently for evidence of sooting. If sooting is present, discontinue
use until source of sooting is determined and corrected.
• Maintain coal positioning (as shown on page 8) at all times.
HOW TO ORDER PARTS
Parts can be ordered through the supplier from whom
you purchased your log set.
When ordering parts, always specify (From information
available on name plate attached to grate) the following:
1. Model number of the log set.
2. Serial number of the log set.
3. Type of gas (natural or propane Gas).
4. The name of the part and part number from parts
list.
◊
Save these instructions
◊
Manufactured By: RASMUSSEN IRON WORKS, INC.
12028 E. Philadelphia Street
Whittier, California 90601
CONSUMER RECORD CARD
Fill in blanks below for your permanent record.
DATE
PURCHASED
MODEL
NO.
DATE
INSTALLED
SERIAL
NO.
INSTALLED
BY:
GAS
TYPE:
DEALER: