3
2. This appliance is for use with the type of gas indicated on the rating plate. This appliance is not field convertible for
use with other gases.
Gas type conversion may only be accomplished at the factory.
3. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control system and any gas control which has been under water.
4. If local valve is not already installed, install a gas valve on the supply line in or just outside the fireplace.
5. A fireplace screen must be in place when the CHILLBUSTER is in operation and, unless other provisions for
combustion air are provided, the screen shall have opening(s) for introduction of combustion air. Glass doors are
not certified with the CHILLBUSTER. However, if used,
Glass Doors must be wide open when the burner is
on
to allow air for safe combustion, cooling of components and venting. Adequate clearances must be provided
around fireplace opening for adequate combustion and proper operation. (see page 5)
ALL APPLICATIONS (INSTALLATION)
Fireplace/Firebox Sizing (VENTED and VENT-FREE):
1. The minimum size (in inches) of the fireplace in which this CHILLBUSTER is to be installed must be as follows:
SET
SIZE
MODEL
NUMBER
FRONTW
IDTH
HEIGHT
DEPTH
11
14
CL-11-C9A-(S,R)-(N,P)
CL-14-C9B-(S,R)-(N,P)
16
20
16
16
9
9
Coal Basket interior Dimension Sizing (VENTED and VENT-FREE):
1. The minimum interior size (in inches) of the Coal Basket in which this CHILLBUSTER is to be installed is as:
SETSIZE
MODELNUMBER
FRONTWIDTH
DEPTH
11
14
CL-11-C9A-(S,R)-(N,P)
CL-14-C9B-(S,R)-(N,P)
13
17
8
8
Gas Supply and Pressure (VENTED and VENT-FREE):
1.
Natural Gas:
The minimum inlet gas supply pressure for the purpose of input adjustment shall be 5 inches of
water column. The maximum inlet gas supply pressure shall be 7 inches of water column.
2.
Propane Gas:
The minimum inlet gas supply pressure for the purpose of input adjustment shall be 11 inches of
water column. The maximum inlet gas supply pressure shall be 14 inches of water column.
The Propane source must be regulated. Never connect CHILLBUSTER directly to an unregulated Propane tank.
Preparation Of Fireplace (VENTED and VENT-FREE):
1. Ensure firebox and chimney damper/flue are thoroughly cleaned (if previously used for gas or wood burning.)
WARNING: Before installing in a solid fuel burning fireplace,
the chimney flue and firebox must be cleaned of soot, creosote, ashes
and loose paint by a qualified chimney cleaner.
2. The area around the CHILLBUSTER must be clear and free from combustible materials, gasoline and any other
flammable vapors and liquids. Provide adequate clearances for servicing and proper operation.
3. Any outside air ducts and/or ash dumps in the fireplace shall be permanently closed at time of installation.
WARNING: Do not use a blower insert, heat exchanger insert or
other accessory not approved for use with this heater.
WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts
that alter burner flame patterns.
Pressure Testing (VENTED and VENT-FREE):
1. Use Propane Gas resistant compound on all pipe fittings (not on connections with flared fitting).
2. The CHILLBUSTER and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The CHILLBUSTER
must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
3. Test new piping for leaks using soap solution.
Do not use open flame to flame test.