9
Fuse
Replacement
1.
Disconnect this product from the power outlet.
2.
Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove the blown fuse and replace with a another fuse of the same type and rating (F 10 A, 250
V).
4.
Screw the fuse holder cap back in place and reconnect power.
Make sure to disconnect the product’s power cord before replacing a blown fuse. Always
replace the blown fuse with another of the same type and rating
Power Linking
The Choas™ supports power linking. You can power link up to 8 products at 120 V;
up to 15 at 208 V; or up to 9 at 230 V. This product comes with a power input cord. Power linking
cables are available from Rasha for purchase.
DMX Linking
You can link the Chaos™ to a DMX controller using a 3- or 5-pin DMX connection. If using other
DMX-compatible products with the Chaos™ R2 Wash, you can control each Individually with a single
DMX controller
DMX
Personalities
The Chaos™ uses a 3- or 5-pin DMX data connection for the 13 or 44 channel DMX personalities.
•
Refer to the
Introduction
chapter for a brief description of each DMX personality.
•
Refer to the
Operation
chapter to learn how to configure the Chaos™ R2 Wash to work in these
personalities.
•
The
DMX Values
section provides you with detailed information regarding the DMX personalities
If you are not familiar with or need more information about DMX standards, Master/Slave connectivity, or the DMX cables
needed to link this product to a DMX controller, download the DMX Primer from the Rasha website:
www.rashaprofessional..com
.
3.
SETUP
Power Supply
Each Chaos has an auto-ranging power supply that works with an input voltage range of 100
to 240 VAC, 50/60 Hz. To determine the power requirements for each Chaos, refer to the label
affixed to the product. You can also refer to the
Technical Specifications
chart in this manual
The listed current rating indicates the maximum current draw during normal operation. For
more information, you may download Sizing Circuit Breakers from the Rasha website:
www.rashaprofessional.com
Always connect this product to a protected circuit with an appropriate
electrical ground to avoid the risk of electrocution or fire.
To eliminate unnecessary wear and improve its lifespan, during periods of non-
use completely disconnect the product from power via breaker or by
unplugging it.
Never connect this product to a rheostat (variable resistor) or dimmer circuit,
even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
AC Plug
The Chaos comes with a power input cord terminated with a Neutrik® powerCON® A
connector on one end and an Edison plug on the other end (U.S. market). If the power input
cord that came with your product has no plug, or if you need to change the Edison plug, use
the table below to wire the new plug.
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green