Raritan PH Superflush Installation And Maintenance Instructions Manual Download Page 5

5

INST

ALLA

TION/PLUMBING

1.  Route discharge hose above discharge 

outlet with a vented loop. This will 

enable the toilet to discharge more 

efficiently  and  will  help  to  prevent 

backflow.

2.  An In-Line Strainer (#163000) is 

recommended.  This will help minimize 

odors and help prevent clogging.

3.   Intake and discharge thru-hull fittings 

should be located far enough apart to 

prevent  discharge  water  from  being 

drawn through the intake.  

4.    The  optional  Raritan  Knocks  Out 

Odors Kit (#KO2) enables the use of 

Cleans Potties (#1PCP22). Raritan 

Cleans Potties deodorizes the bowl and 

lubricates internal parts.

5.  Flush and check for leaks.

PLUMBING

WARNING:  Hazard of Flooding 
Toilets mounted at or below the waterline must have a vented loop installed in the discharge line.  The top 

of the vented loop must be a minimum of 4” (10 cm.) above the waterline at the boats greatest angle of heel 

(see vented loop manufacturer’s instructions).   
Double clamp all below-waterline connections.

IMPORTANT

•  Fittings and 90° bends should be kept to a minimum.
•  In-Line Strainer may be installed.  This will prevent clogs.
•  Discharging untreated sewage is forbidden in all U. S. waters within the three-mile limit.
•  Thru-hull fittings and seacocks must be installed where they are easily accessible.
•  Use only quality reinforced hoses such as Raritan Saniflex (SFH)
•  Secure all hoses properly.

PH SuperFlush 

Toilet

Vent Outside 

Hull or Deck 

 

Waterline

Waterline

Vented 

Loop

In-Line 

Strainer

Intake Thru-Hull 

and Seacock

Discharge Thru-

Hull and Seacock

FIG 4        

FIG 5    

Sanitation Device

*Drawing not to scale

*Drawing not to scale

PH SuperFlush 

Toilet

Waterline

Waterline

Discharge Thru-

Hull and Seacock

Intake 

Thru-Hull and 

Seacock

Vented 

Loops

Sanitation 

Device

Holding Tank

Deck Pumpout

Y Valve

In-Line 

Strainer

Above Waterline Installation

  Below Waterline Installation

L563  0316kgs

Summary of Contents for PH Superflush

Page 1: ...line must have vented loops posi tioned properly and all hose connections should be double clamped Both intake and discharge seacocks should always be in the closed position when the toilet is not in...

Page 2: ...ns IMPORTANT Do not use cleaners that contain ammonia ethyl acetate phosphoric acid or concentrated chlorine bleach These may cause damage to the toilet Using C P a bio enzymatic toilet bowl cleaner 1...

Page 3: ...oseofantifreezeproperly in accordancewithlocalandfederalregulations 3 Reconnectthehosesandopenbothseacocks 4 Check all connections for leaks with several test flushes Inlet Valve Handle Orientation an...

Page 4: ...s Make sure seat will open properly 3 Mark location of toilet base mounting holes on mounting surface 4 Drill holes for toilet mounting bolts screws 5 Secure toilet to surface 2 76 70 8 86 225 4 33 11...

Page 5: ...e the waterline at the boats greatest angle of heel see vented loop manufacturer s instructions Double clamp all below waterline connections IMPORTANT Fittings and 90 bends should be kept to a minimum...

Page 6: ...iphon Close discharge seacock then intake seacock to determine which is causing the problem Clean or replace vented loop s parts Joker valve worn Inspect clean or replace as needed Odor comes from hea...

Page 7: ...e Gasket 2 31 1209BW Valve Handle 32 1124 1 4 20 x 1 2 R H Machine Screw PARTS LIST 33 1217 Discharge Valve Cap 34 LWS Intake and Discharge Valve Spring 2 35 1201 Intake and Discharge Valve Ball 2 36...

Page 8: ...y modifications alterations repairs or service of this product by anyone other than Raritan defects in materials or workmanship supplied by others in the process of installation of this product defect...

Reviews: