5
INST
ALLA
TION/PLUMBING
1. Route discharge hose above discharge
outlet with a vented loop. This will
enable the toilet to discharge more
efficiently and will help to prevent
backflow.
2. An In-Line Strainer (#163000) is
recommended. This will help minimize
odors and help prevent clogging.
3. Intake and discharge thru-hull fittings
should be located far enough apart to
prevent discharge water from being
drawn through the intake.
4. The optional Raritan Knocks Out
Odors Kit (#KO2) enables the use of
Cleans Potties (#1PCP22). Raritan
Cleans Potties deodorizes the bowl and
lubricates internal parts.
5. Flush and check for leaks.
PLUMBING
WARNING: Hazard of Flooding
Toilets mounted at or below the waterline must have a vented loop installed in the discharge line. The top
of the vented loop must be a minimum of 4” (10 cm.) above the waterline at the boats greatest angle of heel
(see vented loop manufacturer’s instructions).
Double clamp all below-waterline connections.
IMPORTANT
• Fittings and 90° bends should be kept to a minimum.
• In-Line Strainer may be installed. This will prevent clogs.
• Discharging untreated sewage is forbidden in all U. S. waters within the three-mile limit.
• Thru-hull fittings and seacocks must be installed where they are easily accessible.
• Use only quality reinforced hoses such as Raritan Saniflex (SFH)
• Secure all hoses properly.
PH SuperFlush
Toilet
Vent Outside
Hull or Deck
Waterline
Waterline
Vented
Loop
In-Line
Strainer
Intake Thru-Hull
and Seacock
Discharge Thru-
Hull and Seacock
FIG 4
FIG 5
Sanitation Device
*Drawing not to scale
*Drawing not to scale
PH SuperFlush
Toilet
Waterline
Waterline
Discharge Thru-
Hull and Seacock
Intake
Thru-Hull and
Seacock
Vented
Loops
Sanitation
Device
Holding Tank
Deck Pumpout
Y Valve
In-Line
Strainer
Above Waterline Installation
Below Waterline Installation