3

If space is limited, the bowl can be rotated 90 degrees
(a longer hose [#CH42] is required, contact Raritan
Technical Support).

PLUMBING

WARNING:

  

If the toilet is mounted at or below

the waterline, install a vented loop in the discharge
line and between the pump and back of the bowl.
The top of the loop (see loop manufacture
specifications) should be at least 4” (10 cm) above
the waterline when the boat is at the greatest angle
of heel (see Fig. #3).

Whenever possible hose connections should be
secured using two all-stainless steel hose clamps.
Integrity of clamps, hoses and fittings should be
checked periodically.  Fittings and 90 degree bends
should be kept to a minimum to maintain proper
performance.

1.   Intake Lines:

  A 3/4” (19mm) thru-hull fitting

Connect a 3/4” (19 mm) I.D. reinforced suction
hose between the seacock and intake pump.

NOTE:  An intake In-Line strainer (#163000) is
recommended to help avoid the accumulation of
debris in the intake pump.

2.  

Discharge Lines: 

Connect quality sanitation rated

1 1/2” (38 mm) I.D. hose (#SH) to the discharge
fitting on the toilet and connect to the treatment
system, holding tank, or discharge thru-hull
fitting, as appropriate.

TIP:  To retain water in the bowl

 

install a vented

loop in the discharge line.

NOTE:  Discharge of raw untreated sewage is
restricted in all U. S. waters inside the three-mile
limit.  “Y” Valves, if installed, must direct toilet
discharge to a USCG approved treatment system
or holding tank and must be secured in that
position while inside the three-mile limit.

WIRING

WARNING:

 

 RISK OF FIRE - The Crown Head

must be wired to a separately fused circuit with
no other electrical appliances on the circuit.

1. Measure wire distance from power source to

toilet and back, refer to Specification Table for
proper wire gauge and circuit breaker/fuse sizes.

12, 24 and 32 VDC Crown Head Units:

  Wire as

per Fig. #4.  (For momentary push button switch
operation.)

Crown Head with Lectra/San

® 

MC

and Vented Loops

Crown Head  with  LECTRA/SAN

® 

MC,

Holding Tank and "Y" Valve

Fig. #2 Above Waterline Installation Shown

Lectra/San EC

Treatment Unit

To

Deck

Pumpout

Lectra/San EC

Treatment Unit

Crown Head

Holding Tank

Discharge

Thru-Hull

 and Seacock

Crown Head

Intake

 Thru-Hull and

Seacock

Discharge

Thru-Hull

And Seacock

Intake

 Thru-Hull

and Seacock

Vented Loop

Pushbutton

Switch

(PBS)

3 Amp Fuse or

 Circuit Breaker

Main Fuse or

Circuit Breaker

(See Specification Chart)

Pos Voltage from

Battery or  DC Power

Panel

Battery

Lug

Solenoid Relay

(CDS)

#14 Awg

Wire

Ground

-

 (Neg)

Crown Head

(Pos)

“Y” Valve

Vented

Loop

Drawing Not to Scale

Fig. #3 At or Below Waterline Installation Shown

Drawing Not to Scale

Fig. #4  Wiring the Crown Head (DC Unit
with Momentary Pushbutton Switch

and seacock located in an accessible area is
required to supply flush water to the bowl.

Summary of Contents for Crown Head

Page 1: ...e a white marine size bowl or household style bowl available in either white or almond OPERATION CAUTION The Crown Head motor is designed to be used as a toilet and is not rated for continuous duty The Crown Head does not require special toilet paper however hard objects or stringy substances paper towels femine hygene products filter cigarettes etc must not be thrown into the toilet as they will ...

Page 2: ... instructions RECOMMISSIONING 1 Using the buckets hoses and a gallon of clean water flushtheantifreezeoutofthetoilet Dispose of antifreeze properly in accordance with local and federal regulations 2 Reconnect the hoses and open both seacocks 3 Check all connections for leaks with several test flushes SYSTEM COMPONENTS Before starting installation please be sure that all parts that were ordered wit...

Page 3: ...ed in all U S waters inside the three mile limit Y Valves if installed must direct toilet discharge to a USCG approved treatment system or holding tank and must be secured in that position while inside the three mile limit WIRING WARNING RISK OF FIRE The Crown Head must be wired to a separately fused circuit with no other electrical appliances on the circuit 1 Measure wire distance from power sour...

Page 4: ...d until the old unit is received by Raritan Subject to parts and production availability exchange units are not always available for shipment Exchange units include the LBA along with a package of fasteners new joker valve mounting strips and a bowl gasket to remount the bowl to the LBA NOTE Pre 11 87 Standard LBA s utilized a flapper valve on the discharge If replacing this model please mention i...

Page 5: ...entrate reservoir empty 3D Refill with 2 oz 59ml Raritan Concentrate CON22 and water 4 Bowl fills while underway 4 Pressure buildup at seacocks 4 Close intake then discharge seacock to determine which is causing problem If intake replace check ball and spring If discharge be sure the vent or vented loop is clean If intake there is too much pressure on seacock contact Raritan Technical Support 5 Co...

Page 6: ...Spring CH90 Discharge Adapter CH92 Adapter Gasket CHM Motor Part No Description F149VT Set Screw 2 G13 Pump Impeller G15 Impeller Washer 2 G13W Pump Impeller w 2 G15 G2M Impeller Wear Plate M23 Lockwasher 4 M30 Hex Nut Brass 2 M31 Flat Washer Brass 2 RNI Nylon Bowl Mounting Washer 4 VCAP Vinyl Cap bowl nut cover MISCELLANEOUS RELATED PARTS Part No Description 1234 Bowl Gasket fits all Raritan toil...

Page 7: ...7 C253 CH37 CH136 CH37E CH29A CH291 or Ch291ALM A ...

Page 8: ...t cover damages to equipment caused by fire flood external water excessive corrosion or Act of God 3 ANYEXPRESSWARRANTYNOTPROVIDEDHEREIN ANDANYREMEDYFORBREACH OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR OPERATION OF LAW IS HEREBY EXCLUDED AND DISCLAIMED ALL IMPLIED WARRANTIES SUCH AS THOSE OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE IF APPLICABLE AS WELL A...

Reviews: