Mounting Atmospheric Vacuum Breaker
(Pressurized Freshwater Model only)
1. Install fittings as shown.
2. Locate mounting area that is a minimum of
6" (15.3cm) above toilet.
3. Secure where top is in horizontal position.
Mounting In-Line Strainer
(Seawater Models Only)
Make sure strainer bowl is tight.
1. Locate strainer where it will be accessible.
2. Mark and drill mounting holes.
NOTE: Hole size will depend on type of bolts/
screws used (1/4" [6mm] size bolts/screws are
recommended).
3. Install fittings provided (#PLA14) on strainer’s
inlet and outlet ports.
4. Mount strainer. Strainer must be mounted
according to flow markings on strainer body.
Mounting Remote Intake Pump
(Sea Models Only)
1. Locate on a flat solid surface in an area that is
dry and well ventilated.
NOTE: Location should not be greater than 48"
(122cm) above the waterline.
2. Mark and drill mounting holes.
NOTE: Hole size will depend on type of bolts/
screws used (1/4" [6mm] size bolts/screws are
recommended).
3. Mount pump. Do not over tighten bolts.
Installing Lower Cover
1. Slide cover over lower unit.
2. Secure in place with plastic beaded tie.
NOTE: Do not install until installation is
completed.
INSTALLATION
Flow Marking
6"
(15.3cm)
➔
➔
9