C
LIENT
19
7.
If you selected
Power On
or
Power Off
in the
Operation
field and more than one interface
in the
Selected
list, type the number of seconds, from 0-120, that should elapse between
interfaces in the
Sequence Interval (seconds)
field.
8.
Click
OK
to begin the power control operation.
Note: Nodes of an iLO/RILOE device are powered on/off and recycled directly. Nodes connected
to Raritan Dominion devices, such as KX and SX, are managed via outlets of a power strip that
are associated with a port of a Dominion device.
Managing Power to an IPMI Server Node
IPMI Server nodes can be directly powered on/off, recycled, or gracefully shutdown through the
associated power control IPMI interface.
1.
In the
Nodes
tree, select the IPMI Server node you want to manage power to. The Node
Profile screen appears.
2.
In the Node Profile screen, all configured interfaces display in the Interfaces section.
3.
In the Name column, click the hyperlink of the power control IPMI interface you want to use
to control power to the IPMI server node. The
Power Control
screen appears.
Figure 18 Power Control Screen for an IPMI Server Node
4.
The selected node’s name displays in the
Node
field.
5.
In the
Available
list, select the power control IPMI interface through which you want to
manage power for the node, and then click
Add
to move the interface to the
Selected
list.
6.
Click the
Operation
drop-down arrow, and select
Power On
,
Power Off
,
Power
Cycle
, or
Graceful Shutdown
from the list.
7.
If you selected
Power On
or
Power Off
in the
Operation
field and more than one interface
in the
Selected
list, type the number of seconds, from 0-120, that should elapse between
interfaces in the
Sequence Interval (seconds)
field.
8.
Click
OK
to begin the power control operation.
9.
Repeat the steps in this section to manage power for other IPMI Server nodes.