      START UP

Refer to Start Up procedure outlined in the Lectra/San 

or Electro-Scan Manual. The following instructions 

are supplementary to those instructions (see Fig. #3).

1.  Check plumbing connections.

2.  Turn on water supply.

3.  Check for leaks.

4..  Fill tank with solar salt.

How to adjust the salt solution:  

Open plastic tubing 

clamp completely. Flush toilet several times then 

run a treatment cycle. There should be no low salt 

indication.  See Owner’s Manual for specific system to 

see how low salt is indicated, as it varies from model 

to model. Use Troubleshooting if low salt indication 

continues.  With no low salt indication start closing 

plastic tubing clamp until low salt indication comes 

on and open plastic tubing clamp slightly again for 

optimum salt without low salt indication.  Flush toilet 

four times between each adjustment.

Fig. #3  Raritan’s PHII Manual Toilet Shown with Four    

Gallon Salt Feed System

Fig. #4  Electric Toilet with remote intake pump and Four  

 

Gallon Salt Feed System

L288B   0917jlc                                                                                                         

Remove

Check Ball

(1201)

and Spring

(LWS)

Seawater 

Inlet

T-Check Valve 

Assy.

(31-307W)

Pressurized Fresh 

Water Supply

Shutoff Valve

Overflow Hose 

Plumbed to Bilge

Seawater 

Inlet

T-Check Valve 

Assy.

(31-307W)

Overflow Hose 

Plumbed to Bilge

Pressurized Fresh 

Water Supply

Shutoff Valve

Summary of Contents for 31-3005

Page 1: ...reatment Tank can be decreased or increased by adjusting the plastic tubing clamp 31 304C To FOUR GALLON SALT FEED SYSTEM Part 31 3005 Installation and Maintenance Instructions decrease the amount of salt solution entering system adjustplastictubingclamptopinchtubingrestricting flow To increase the amount of salt solution release plastic tubing clamp to remove restriction See Start Up section for ...

Page 2: ...mbers refer to toilet parts and not in the T Check valve When connecting to a PHII remove 1201 and LWS for Crown Heads remove CH12 and CH8 for CrownHeadIIandAtlantesmodelsreplace RCV with T Check valve provided Other types of toilets need not be modified unless they have an additional built in check valve 7 Install overflow hose to bilge 8 Connect pressurized freshwater with a shutoff valve to the...

Page 3: ...oubleshooting if low salt indication continues With no low salt indication start closing plastic tubing clamp until low salt indication comes on and open plastic tubing clamp slightly again for optimum salt without low salt indication Flush toilet four times between each adjustment Fig 3 Raritan s PHII Manual Toilet Shown with Four Gallon Salt Feed System Fig 4 Electric Toilet with remote intake p...

Page 4: ...efects caused by installation of this product other than in accordance with the manufacturer s recommended installation instructions or standard industry procedures physical abuse to or misuse of this product This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosion or Act of God 3 ANYEXPRESSWARRANTYNOTPROVIDED HEREIN ANDANYREMEDYFOR BREACH OF C...

Reviews: