7 |
P a g e
RAPID TOOL Australia Pty Ltd
+61 2 8090 5999 | [email protected]
www.rapidtool.com.au
No.
Normal Operation
Problem
Warning
Sound
Cause
What to Check
Solution
Seven short
beeps
repeated
There is foreign substance
between Magnetic plate (#61)
and Route PWB unit (#62) or
bad connection of connecting
wire K.
Check if there is foreign
substance between Magnetic
plate (#61) and Route PWB
unit (#62) or check the wire K
connection.
Remove the foreign substance
between Magnetic plate (#61)
and Route PWB unit (#62) or
replace with new connecting
wire K.
Four short
beeps
repeated
Bad connection of connecting
wire A and B or twisting motor
is burned.
Check the wire A and B
connection.
Reconnect or replace the wire A
and B or replace with new
twisting motor.
Binding power is
weak.
No sound
emitted.
Reinforcing bar is not of
designated size.
Confirm size of reinforcing
bars to be bound.
Use approriate diameter scope.
Erroneous handling such as
improper application of
machine.
Confirm how to apply machine
to reinforcing bars.
Adjust the tension setting to a
higher lever and ensure
machine is held as per correct
usage section below.
Twisting-off tie
head occurs.
No sound
emitted.
Reinforcing bar is not of
designated size.
Confirm size of reinforcing
bars to be bound.
Use approriate diameter scope.
Erroneous handling such as
improper application of
machine.
Confirm how to apply machine
to reinforcing barts.
Adjust the tension setting to a
lower lever and and ensure
machine is held as per correct
usage section below.
Works properly.
Two long
beeps
repeated
Low power remains in the
battery pack.
Confirm the battery is fully
charged.
Perform normal charge.