5.1.2.1
Pump: Refer to fig.2. Use a ground wire and clamp
as shown in fig.2. Remove the ground screw 1,
onto the pump and tighten securely. Connect the other
end of the ground wire to a true earth ground. Insert
through the eye of the ring terminal at end of the
ground wire 2. Fasten the ground screw back.
5.1.2.2
Air and fluid hoses: Effectively grounding.
5.1.2.3
Air compressor: Follow the manufacturer‘s
recommendations.
5.1.2.4
Control valve: Use proper grounding line to connect
the pump. Keep the metal part of the control valve
connected with the grounding equipment.
5.1.2.5
Barrel: Use the barrel which is under the permission of local area. If it is a
metal barrel, put in on the ground which is with electric capability. If noc
grounding paper or board, it is not allowed to put on the surface of non-
conductor directly.
5.1.2.6
Other components: Comply with local grounding requests.
5.1.2.7
Keep effective grounding when working or pressure releasing.
5.2 Installation
5.2.1
Typical installation: Refer to fig.3:
1
Bleed-type master air valves
2
Air line filter
3
Air regulator with gauge
4
Air line lubricator
5
Pump runaway valve
6
Drum cover
7
Follower plate
8
Hose reel
Above typical installation is not for whole system
design. If any help needed, please contact us or local agent.
5.2.2
Installation of air line
5.2.2.1
Note: Do not hang any equipment to the air inlet as it may cause falling
down by poor hanging equipment.
5.2.2.2
Process
5.2.2.2.1 Install a pump on drum cover (see fig.3 part 6) and then tp barrel.
5.2.2.2.2 On the main line of air compressor, connect bleed-type master air valves
which controls on and off air motor (see fig.3 part 2)
5.2.2.2.3 Install an air line filter (see fig.3 part 2) to remove harmful dirt and
contaminants from your compressed air supply.
5.2.2.2.4 Install the air regulator to control pump speed and pressure. (See fig.3
part 3)
5.2.2.2.5 Install an air line regulator for automatic air motor lubrication (see fig.3
part 4).
5.2.2.2.6 Install a pump run-away valve to shut off the air to the pump if the pump
accelerates beyond the pre-adjusted setting. A pump that runs too fast
can be seriously damaged. (See fig.3 part 5)
5.2.2.2.7 Connect outlet line.