9060 High Voltage Controller - Installation
17
CP-13-05.3
GENERAL INFORMATION
The following section contains general infor-
mation on the installation of both local and
remote systems using the 9060 High Voltage
Controller.
INSTALLATION
The 9060 Controller
MUST
be located
outside of the hazardous area.
The User
MUST
read and be familiar
with the “Safety” section of this manual.
This manual
MUST
be read and thor-
oughly understood by
ALL
personnel who
operate, clean, or maintain this equipment!
Special care should be taken to ensure that
the warnings and requirements of operating
and servicing safely are followed. The user
should be aware of and adhere to ALL local
building and fire codes and ordinances as
well as NFPA-33, OSHA, and all related
country safety codes prior to installing, op-
erating, and/or servicing this equipment.
Only approved applicators should be
used with the 9060 High Voltage Controller.
!
W A R N I N G
DO NOT
locate the Controller near or
adjacent to heat producing equipment
such as ovens, high wattage lamps, etc.
!
C A U T I O N
As each installation is unique, this infor-
mation is intended to provide general in-
stallation information for the 9060 Control-
ler. Consult your authorized Ransburg
distributor for specific directions pertaining
to the installation of your equipment.
N O T E
The Controller may be free standing on any flat
surface or wall mounted (wall mount brackets
not supplied) as shown in Figure 5.
Figure 5: Typical Controller Mounting
LOCATION OF THE 9060
Install the Controller in an area
outside the
hazardous location
in accordance with feder-
al, state, and local codes. The area should
protect the Controller from the possibility of
environmental intrusion (such as dust or mois-
ture), have ambient temperatures that do not
exceed 40°C, and be as close to the applicator
as possible to minimize the length of the high
voltage cable.