Check the Water Level
Water coming in from the Air Source is pulled out of the incoming air by the Regulator/Filter and
dropped into the reservoir at the bottom.
This water needs to be drained periodically.
To drain water from the Regulator/Filter reservoir
:
1.
Check the Water Sight Gauge to see how much water is currently in the reservoir.
If the reservoir is one quarter (25%) or more filled with water, you need to drain it.
2.
Disconnect the Air Source at the Air In connector.
⚠
WARNING
Make sure to disconnect the Air Source and make sure it cannot be reconnected
until you are done draining the water from the Regulator/Filter. If the Air Source is
reconnected during the procedure, it could damage the Regulator/Filter, the Tire
Changer, and possibly injure bystanders.
3.
Press upwards on the Water Drain Plug at the bottom of the reservoir.
The water drains out.
4.
Release the Water Drain Plug.
5.
Re-connect the Air Source.