14
SECTION 10
ELECTRICAL SOURCE
This unit requires power from a 15 amp electrical circuit.
The unit is supplied standard with a 110 Volt power cord
and plug. (See Fig. 10.1)
Refer to the serial tag of the machine for specific
electrical requirements. Have a licensed electrical
technician perform any necessary changes to the power
source and power cord before plugging in the unit. The
electrical source must have a solid connection between
ground and building ground.
WARNING!
GUARD AGAINST ELECTRIC SHOCK
.
This equipment must be grounded while in use to protect
the operator from electric shock. Never connect the green
power cord wire to a live terminal. This is for ground only.
DANGER!
The motor on this machine contains high voltage.
Disconnect power at the receptacle before performing any
electrical repairs. Secure plug so that it cannot be
accidentally plugged in during service.
WARNING!
RISK OF EXPLOSION
.
This equipment has internal arcing or sparking parts which
should not be exposed to flammable vapors.
This machine should not be located in a recessed
area or below floor level.
Fig. 10.1