18
8. Technical Data
THE HOB IS CATEGORY:
II2H3+.
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the cooker.
INSTALLER:
Please leave these instructions with the User.
DATA BADGE LOCATION:
Hotplate base.
COUNTRY OF DESTINATION:
GB, IE.
Connections
Gas
(Rp ½ at rear right-hand side)
Electric
Natural gas
20 mbar
230/400 V 50 Hz
Butane
29 mbar
Propane
37 mbar
See the appliance badge for test pressures.
Dimensions
Overall width
1173 mm
Overall depth
499 mm
Minimum height to the hotplate
650 mm
Refer to
‘Positioning the Hotplate’.
Ratings
Hotplate
Bypass Screw*
Natural Gas 20 mb
LP Gas
Injector
Injector
Wok burner
57
3.5 kW
internal 78
3.5 kW (246 g/h)
internal 53
external 126
external 82
Large burner
40
3.0 kW
134
3.0 kW (210 g/h)
87
Medium burner
32
1.7 kW
109
1.7 kW (119 g/h)
68
Small burner
28
1.0 kW
75
1.0 kW (70 g/h)
51
* The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for
Natural gas. For LPG conversion the bypass screws must be screwed all the way down.
Maximum total electrical load at 230 V
(approximate total)
:
50 W.