WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
15
Check in the
‘Technical Data’
section at the back of the
book that the hotplate is convertible to the gas you want
to use.
This conversion must be performed by a competent person.
After conversion the installation must comply with the
relevant regulations and also the local electricity supply
company requirements. Read the instructions before
converting this appliance.
n
n
Failure to convert the appliance correctly could
invalidate any warranty or liability claims and lead
to prosecution.
n
n
This instruction must be used in conjunction with
the rest of the appliance instruction, in particular
for information on Standards, hotplate positioning,
connection hose suitability, etc.
n
n
When servicing or replacing gas-carrying
components disconnect from gas before
commencing operation and check appliance is gas
sound after completion.
n
n
DO NOT use reconditioned or unauthorised gas
controls.
n
n
Disconnect from the electricity supply before
servicing.
n
n
Before electrical reconnection, check that the
appliance is electrically safe.
Injectors
Remove the burner caps and heads. Remove the old jets
(Fig.6-1)
. Fit the new jets (see
‘Technical Data’
section at the
back of the book for correct jets). Reassemble in the reverse
order.
Tap Adjustment
Pull off all the control knobs and remove the two hexagon
headed screws (which act as locators for the pan support),
from the edge of the hotplate under the right-hand pan
support
(Fig.6-2)
.
Slide the glass to the right slightly and lift it from the side
(Fig.6-3)
. Carefully lift the panel clear of the hotplate and
place it somewhere safe. The tap bypass screws are now
accessible once the bezel location brackets are removed.
Turn the bypass screw on each control clockwise to the stop
(Fig.6-4)
.
Refit the glass panel and replace the fixing screws in the top
edge of the hotplate.
Carefully replace the control sealing rings and replace the
control knobs.
Stick on Label
Stick the LP gas label over the natural gas part of the
appliance data label.
6. Conversion to LP Gas
A
B
C
ArtNo.311-0010 Injectors
A – Jet, B – Internal injector, C – External injector
ArtNo.0102-0011 - Screwing
the control valve bypass screw
Fig.6-1
Fig.6-2
Fig.6-3
Fig.6-4