WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
16
Pressure Testing
Connect the appliance to the gas supply. Check the appliance
is gas sound.
The gas pressure can be measured at one of the left-hand
hotplate burner jets (not the wok burner).
Lift off a burner head. Fit the pressure gauge to the jet. Turn
on and light one of the other burners with a match. Turn on
and press in the control knob for the burner with the pressure
guage fitted.
The pressure should be 29 mbar for Butane and 37 mbar for
Propane. After checking the pressure, turn the taps off and
replace the burner head.
Reassemble the burner top, making sure it is reassembled in
the correct way on the burner body.
Check the appliance is gas sound.
Check operation of all the burners.